b. Gas Connections: |
|
Inlet connection | 3/4” inch N.P.T. |
Inlet supply size | 3/4” inch N. P.T. |
Btu/hr input (per dryer) | 200,000 |
1. Natural Gas |
|
Regulation is controlled by the dryer’s gas valve’s internal regulator. Incoming supply pressure must be consistent between 6 and 12 inches water column pressure.
2. Liquid Propane (L.P.) Gas
Dryers made for use with L.P. gas have the gas valve’s internal pressure regulator blocked open so that the gas pressure must be regulated upstream of the dryer. The pressure measured at each gas valve pressure tap must be a consistent 11 inch water column. There is no regulator or regulation provided in an L.P. dryer. The water column pressure must be regulated at the source (L.P. tank) or an external regulator must be added to each dryer.
|
|
|
| Type of Gas |
|
|
| L.P. | |
|
|
|
|
|
|
|
|
| |
|
|
| Natural |
|
| Liquid Propane | Conversion | ||
|
|
|
|
|
|
|
|
| Kit Part |
Model | BTU Per |
|
| Part |
|
|
| Part | |
|
|
|
|
| Number | ||||
Hour | Qty. | D.M.S.* | Qty. |
| D.M.S.* | ||||
Number | Number |
| Number |
| |||||
Rating |
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| |
ML79 WW | 200,000 | 4 | #29 | 4 | 4 |
| #47 | 140805 | 881231 |
|
|
|
|
|
|
|
|
|
|
*D.M.S. (Drill Material Size) equivalent are as follows:
Natural Gas | #29 = .1360” |
Liquid Propane Gas | #47 = .0785” |
3. Piping and Connections
ALL components and materials must conform to National Gas Code specifications. It is important that gas pressure regulators meet applicable pressure requirement and that gas meters be rated for the total amount of ALL the appliance BTU’s being supplied.
The dryer is provided with a 3/4” N.P.T. inlet pipe connection located at the right side of the base of the dryer. The minimum pipe size (supply line) to the dryer is 3/4” N.P.T. For ease servicing, the gas supply line of each dryer must have its own
The size of the main gas supply line (header) will vary depending on the distance this line travels from the gas meter or, in the case of L.P. (liquid propane) gas, the supply tank, other
NOTE: Undersized gas supply piping can create a low or inconsistent pressure which will result in erratic operation of the burner ignition system.