H. AIR INFORMATION

1.Air Jet System

The ML-79WW is manufactured with a Pneumatic Air Jet system which requires an external supply of compressed air. The air connection is made to a three way micro valve located on the rear electric relay box cover.

IMPORTANT: The condensation filter must be checked and drained every thirty days. This will vary depending on the amount of equipment usage.

NOTE: Drain bowls with manual drain to keep accumulated liquids below element. Liquid will be carried downstream if it reaches the element. Replace element when plugged.

A.Air Requirements

1.The air supply required to operate this dryer correctly is regulated at 40 p.s.i. Any deviation from this may cause damage to the outlet humidity sensor.

B.Air Connection

1.The air connection to the dryer is of 1/8” N.P.T.

2.The air connection for gas only is located in the rear of the dryer on the upper left.

3.The air connection for electric only is located in the upper right side in the rear of the dryer.