SETUP
SETUP - Internal Jumper Switches
Data Buffer Module Switches
The 2010DB Data Buffer Module serves a dual purpose. First,
it sends video to the monitors and second, it filters incoming
information from the high speed LAN line.
Filtering is accomplished with two 8-position DIP switches, S2
and S3. Switch position 1 of switch S2 turns the filter "ON" or
"OFF." If S2 is set to"ON", all information passes and S3 does
not have to be set. If S2 is set to "OFF", only specified
information passes and S3 must be set. The S3 switch allows
only the necessary information to pass for that particular bay.
In the Condensed Bay configuration, or when a bay
contains 2024VOM monitor modules, the filter is set such
that all information passes. Therefore, position 1 of switch
S2 is set to ON.
For all other configurations the filter is set such that
information is filtered, thus position 1 of switch S2 is set to
OFF and S3 must be set accordingly. This applies to bays
which contain only 2016 VIM camera modules.
The Data Buffer Module also has a 2-position slide switch, S1.
S1 switches the card into either a normal mode or test mode.
S1 should be kept at the normal position.
Figure 25 shows the location of these switches on the 2010DB
PCB card.
Table 1 - S2 and S3 switch settings
1=On; 0=Off; X=Don't care
Switch S2
Filter 1 2 3 4 5 6 7 8
Pass all information (S2 ON) 10 XXXXXX
Pass only specified information (S2 OFF) 00 XXXXXX
Note: S2 must be set to pass all information (ON) in
bays which contain 2024VOM monitor modules.
Switch S3
Camera Monitor 1 2 3 4 5 6 7 8
1-256 1-16 X X 0 0 X 0 0 X
257-512 1-16 X X 1 0 X 0 0 X
513-768 1-16 X X 0 1 X 0 0 X
769-1024 1-16 X X 1 1 X 0 0 X
1-256 17-32 X X 0 0 X 1 0 X
257-512 17-32 X X 1 0 X 1 0 X
513-768 17-32 X X 0 1 X 1 0 X
769-1024 17-32 X X 1 1 X 1 0 X
1-256 33-48 X X 0 0 X 0 1 X
257-512 33-48 X X 1 0 X 0 1 X
513-768 33-48 X X 0 1 X 0 1 X
769-1024 33-48 X X 1 1 X 0 1 X
1-256 49-64 X X 0 0 X 1 1 X
257-512 49-64 X X 1 0 X 1 1 X
513-768 49-64 X X 0 1 X 1 1 X
769-1024 49-64 X X 1 1 X 1 1 X
12
CAUTION - Due to the presence of non-insulated
components with hazardous voltages, the
following internal adjustments should be
performed by qualified service personnel only.
1
8
1
8
S3
S2
S1
Figure 25 - Data Buffer Card Switches