POWERING UP
The system may be brought on line after:
- The CPU has been installed and connected.
- A video input has been connected.
- A monitor has been connected for viewing the output.
- All lines have been properly terminated.
- One keyboard (or external computer) has been connected for
control.
- Power has been connected to the equipment, one bay at a
time, ending with the CPU.
Powering the Matrix Bay
1. Unscrew the two thumbscrews located at the top corners of
front panel of each matrix switching bay.
2. Remove the front panel by first slowly pulling the top of the
panel towards the front, then lifting the panel up.
Note: DO NOT remove the foam material attached to the
front panel.
3. Verify that the unit is turned off. The unit is turned off by
pressing the bottom of the front panel power On/Off switch.
4. Power is supplied via a pendant cord and plug. Connect the
pendant cord to the required voltage input:
AD1024R 120VAC, 50/60 Hz
ADS1024RX 230VAC, 50/60 Hz
5. To turn the unit on, press the top of the front panel power
On/Off switch.
Replace the front panel only after all setup adjustments have
been made related to powering up instructions (Power Supply
Module and Video Output Module, prior pages).
6. To replace the front panel, slip the bottom of the panel into
the slot at the bottom of the bay. Push the top of the panel
towards the bay and tighten the two corner thumb screws.
POWER UP
19