AD2150/AD2350

Supported Protocol

RS-422 (1)

Maximum Presets

16 (2) or 60 (3)

Maximum Patterns (4)

3

Quick Set Menu

Not supported

Address Range

1-32

Notes:

(1)Requires the AD2083-02 series code converter.

(2)Preset information is stored at the converter, not the dome.

(3)Requires AD2083-02 with firmware version 0701- 11YB-156A or newer. Preset information is stored in the dome, not the converter.

(4)Patterns are limited by time and the number of available dome commands. Total time for each pattern cannot exceed 6 minutes 50 seconds. Total dome commands used in all patterns cannot exceed 99.

AD1650

Supported Protocol

RS-422 (1)

Maximum Presets

16 (2) or 60 (3)

Maximum Patterns (4)

3

Quick Set Menu

Not supported

Address Range

1-128 (5)

Notes:

(1)Requires the AD2083-02 series code converter.

(2)Preset information is stored at the converter, not the dome.

(3)Requires AD2083-02 with firmware version 0701- 11YB-156A or newer. Preset information is stored in the dome, not the converter.

(4)Patterns are limited by time and the number of available dome commands. Total time for each pattern cannot exceed 6 minutes 50 seconds. Total dome commands used in all patterns cannot exceed 99.

(5)Requires additional equipment to achieve these numbers. A dome address within each group of 64 or 99 cameras is reserved as a global broadcast address.

AD168

Supported Protocol

SensorNet (1)

 

RS-422 (1) or (2)

Maximum Presets

16 (1)(2), 64 (1)(3), or

 

60 (4)

Maximum Patterns (5)

3

Quick Set Menu

Not supported

Address Range

SensorNet: 1-180

 

RS-422: 1-99 (1)(6) or

 

1-180 (2)(6)

Notes:

 

(1)Requires the appropriate code control module.

(2)Requires the AD2083-02 series code converter.

(3)Presets information is stored at the converter or control module, not the dome.

(4)Requires AD2083-02 with firmware version 0701- 11YB-156A or newer. Preset information is stored in the dome, not the converter.

(5)Patterns are limited by time and the number of available dome commands. Total time for each pattern cannot exceed 6 minutes 50 seconds. Total dome commands used in all patterns cannot exceed 99.

(6)Requires additional equipment to achieve these numbers. A dome address within each group of 64 or 99 cameras is reserved as a global broadcast address.

AD2050

Supported Protocol

RS-422 (1)

Maximum Presets

16 (2) or 60 (3)

Maximum Patterns (4)

3

Quick Set Menu

Not supported

Address Range

1-1024 (5)

Notes:

(1)Requires the AD2083-02 series code converter.

(2)Preset information is stored at the converter, not the dome.

(3)Requires AD2083-02 with firmware version 0701- 11YB-156A or newer. Preset information is stored in the dome, not the converter.

(4)Patterns are limited by time and the number of available dome commands. Total time for each pattern cannot exceed 6 minutes 50 seconds. Total dome commands used in all patterns cannot exceed 99.

(5)Requires additional equipment to achieve these numbers. A dome address within each group of 64 or 99 cameras is reserved as a global broadcast address.

SPEEDDOME ULTRA VII CAMERA DOME CONFIGURATION UTILITY OPERATOR’S MANUAL SUPPLEMENT

8200-0184-09, REV. A

8 of 13