Setting the Auto Pan Speed
1.Press and hold A/P key.
2.Move joystick to Pan Right until the desired speed is observed on the monitor.
3.Release the A/P key.
4.Release the joystick
Activating Auto Pan
Auto Pan allows the dome to continuously pan between the left and right scan limit settings. To start Auto Pan, press the A/P key. If no scan limit settings are programmed, the dome pans to the right continuously.
Note: Auto Pan will be cancelled if the operator issues a Pan, Flip, Preset, or
Pattern command.
Wiring Configurations
In Vicon systems where the domes support loop through, daisy chain the SpeedDome Ultra VII domes off the last Vicon dome in the communications chain.
Figure
To controller or other domes
In Out In Out
Command Response
Vicon dome
SpeedDome | SpeedDome |
Ultra VII dome | Ultra VII dome |
Vicon Protocol Command Summary |