Setting the Auto Pan Speed

1.Press and hold A/P key.

2.Move joystick to Pan Right until the desired speed is observed on the monitor.

3.Release the A/P key.

4.Release the joystick

Activating Auto Pan

Auto Pan allows the dome to continuously pan between the left and right scan limit settings. To start Auto Pan, press the A/P key. If no scan limit settings are programmed, the dome pans to the right continuously.

Note: Auto Pan will be cancelled if the operator issues a Pan, Flip, Preset, or

Pattern command.

Wiring Configurations

In Vicon systems where the domes support loop through, daisy chain the SpeedDome Ultra VII domes off the last Vicon dome in the communications chain.

Figure F-1: SpeedDome Ultra VII dome loop-through wiring from Vicon dome

To controller or other domes

In Out In Out

Command Response

Vicon dome

SpeedDome

SpeedDome

Ultra VII dome

Ultra VII dome

Vicon Protocol Command Summary

F–5