Secure Ethernet Gateway

SEG-1 and SEG-M

for IEI Access Systems

Installation Manual

Section 1: Introduction

SECURITY WARNING: New SEG's shipped after April 2008 will have Telnet setup option enabled by default. Enabling Telnet on the SEG allows you (the customer) to be able to configure the settings of the SEG via LAN without requiring the serial connection to the SEG via the “Gateway Config” RJ11 adapter. While enabling Telnet setup was done as a convenience to speed setup, it also opens a security hole in the SEG. It is recommended that when you are finished setting up the SEG, that you also enable the Telnet password option, so that a password is required to enter Telnet in the future. This Telnet password option is located in Setup menu option named “0 Server Configuration” and when you get to “Change telnet config password” enter Y and then enter a 4 digit password. You can also completely disable Telnet in the menu named “6 Security”.

The SEG is a LAN/WAN (TCP/IP to serial) interface that enables existing or new IEI access systems to use the end user's network infrastructure and to be programmed and managed at any network PC running Hub Manager™ Professional software. The SEG requires Hub Manager™ Professional software version 5.0 or higher for static IP addressing and version 7.1 or higher for dynamic addressing. The access system data sent over the corporate network is 128-Bit so that user and door information cannot be "sniffed" and security compromised.

The IP address assigned to the SEG may be either a static address assigned by authorized network administrator, or it may be a dynamic address assigned by a DHCP Server.

IMPORTANT NOTE:

To set up the SEG, installation technicians must have a technical knowledge of networks and networking in a PC environment. It is important to consult the end user's system administrator in order to resolve any networking issues that may occur.

Ordering Information

Model

p/n

Description

 

 

 

 

 

IEI Secured Ethernet Gateway. Converts TCP/IP to serial data enabling IEI access

 

 

systems to use a network to securely send and receive data; and to be programmed and

SEG-1

0296005

managed from any network PC running Hub Manager Professional. Requires network

connection. Wall mounts using separately provided hardware; requires separate 12VDC

 

 

 

 

power [150 mA max], provided with modular cord for communication with access

 

 

panel.

 

 

 

 

 

IEI Secured Ethernet Gateway [Plug-in] Module. Converts TCP/IP to serial data

 

 

enabling IEI access systems to use a network to securely send and receive data; and to

SEG-M

0296006

be programmed and managed from any network PC running Hub Manager Professional.

 

 

Requires network connection. Easily plugs into backplane which provides module

 

 

power and communication with access panel.

 

 

 

Document Number: 6066005, Rev 3.2