Operation

Alarm conditions

You configure warning and alarm limits through the internal menus,

 

using a serial port connection.

 

The Rack PDU shows warning and alarm conditions as follows:

 

 

 

 

 

Phase Indicator LED

Displays yellow for a warning and red for an

 

 

 

alarm.

 

 

 

 

 

 

Digital Display

If one phase is at or above the warning or

 

 

 

alarm limit, the display shows the current for

 

 

 

that phase.

 

 

 

If more than one phase is at or above the

 

 

 

warning or alarm limit, the display cycles

 

 

 

among those phases, displaying their current.

 

 

 

 

 

 

Control Button

Pressing this button causes the digital display

 

 

 

to display the current for the next phase for 30

 

 

 

seconds. Then it returns to the display of the

 

 

 

current for any phases that are at or above the

 

 

 

warning or alarm limits.

 

 

 

 

 

Do not exceed the maximum voltage and

current ratings listed on the rear panel of

Warning the Rack PDU.

12

Three-Phase Rack PDU — Installation and Operation Manual

Page 16
Image 16
American Power Conversion AP7602, AP7608, AP7601 operation manual Alarm conditions, Using a serial port connection