ELECTRICAL INSTALLATION INSTRUCTIONS

All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes.

WARNING:

When using electrical products, basic precautions should always be observed, including the following:

1.DANGER: RISK OF ELECTRIC SHOCK

Connect only to a circuit protected by a ground-fault circuit interrupter.

2.Grounding is required. The unit should be installed by a licensed electrician and grounded.

3.Install to permit access for servicing.

4.All building materials and wiring should be routed away from the pump body and heater (if equipped).

1.6 HORSEPOWER MODELS:

The whirlpool should be installed on a 120 vac, 15 amp dedicated circuit. The circuit should be hard-wired from the electrical power supply panel. The circuit must be a three (3) wire circuit from the electrical supply panel. A grounded neutral wire and a third wire, earth ground, are essential. ADDING THE SAFE-T-HEATER REQUIRES A SEPARATE 15 AMP MAXIMUM GFCI CIRCUIT.

2.1 HORSEPOWER MODELS:

The whirlpool should be installed on a 120 vac, 20 amp dedicated circuit. The circuit should be hard-wired from the electrical power supply panel. The circuit must be a three (3) wire circuit fron the electrical supply panel. A grounded neutral wire and a third wire, earth ground, are essential. ADDING THE SAFE-T-HEATER REQUIRES A SEPARATE 15 AMP MAXIMUM GFCI CIRCUIT.

ELECTRICAL INSTALLATION

SEPARATE 15 AMP GFCI

or

SEPARATE 20 AMP GFCI

FOR 1.6HP MODELS

FOR 2.1HP MODELS

 

 

120 VAC

 

WHIRLPOOL MOUNTED

 

AIR or ELECTRONIC SWITCH

 

or

 

WALL TIMER-(1.6HP MODELS ONLY)

WHITE

BLACK

 

PUMP/MOTOR

 

GND.

ELECTRICAL DIAGRAM

READ AND FOLLOW ALL INSTRUCTIONS

752352-100 REV. h

(3)

Page 3
Image 3
American Standard 2703.XXXW Series Whirlpool Mounted, Wall TIMER-1.6HP Models only, White Black PUMP/MOTOR GND