WATER PIPING - MIXING VALVE USAGE

SUGGESTED PIPING

ARRANGEMENT

FOR TOP

CONNECTIONS

SHUT-OFF VALVE

TEMPERED POTABLE WATER

COLD WATER

INLET

THERMAL

EXPANSION

TANK

MIXING

VALVE

(OPTIONAL)

PIPE INSULATION (RECOMMENDED)

METAL

DRAIN PAN

TEMPERED POTABLE WATER

TEMPERATURE- PRESSURE RELIEF VALVE

DISCHARGE

PIPE (DO NOT CAP OR PLUG)

6 in. (15cm)

MAX.

AIR GAP

DRAIN VALVE

FLOOR

TO SUITABLE DRAIN

 

DRAIN

FIGURE 3

This appliance has been design certified as complying with

CPVC, PEX or polybutylene. DO NOT use PVC water

ANSI Z21.10.3/CSA 4.3 (latest revision) for water heaters

piping.

and is considered suitable for:

DO NOT use any pumps, valves, or fittings that are not

Water (Potable) Heating: All models are considered

compatible with potable water.

suitable for water (potable) heating.

DO NOT use valves that may cause excessive restriction

 

to water flow. Use full flow ball or gate valves only.

The Hybrid water heater is a unique design that it combines

DO NOT use any lead based solder in potable water

the technology of both the storage tank and tankless type

lines. Use appropriate tin-antimony or other equivalent

water heaters. A tankless water heater ensures a fixed

material.

constant outlet water temperature, this is achieved by

DO NOT tamper with the gas control/thermostat, igniter,

modulating the water flow to ensure that this temperature

flammable vapor sensor or temperature and pressure

is maintained. In the Hybrid the water supply is heated

relief valve. Tampering voids all warranties. Only qualified

as it flows through the heat exchanger over the burners

service technicians should service these components.

similar to the tankless water heaters. The heated water is

DO NOT use with piping that has been treated with

than stored in the top of the storage tank.

chromates, boiler seal, or other chemicals.

The tank outlet water temperature will be within a maximum

DO NOT add any chemicals to the system piping which

of 5°F (2.8°C) of the display set-point when the unit ends

will contaminate the potable water supply.

the call for heat.

 

If required by local codes or if a higher fixed temperature

HOTTER WATER CAN SCALD:

is required, a mixing valve can be installed as shown on

Water heaters are intended to produce hot water. Water

Figure3.

heated to a temperature which will satisfy space heating,

 

clothes washing, dish washing, and other sanitizing needs

Please note the following:

can scald and permanently injure you upon contact. Some

The system should be installed only with piping that is

people are more likely to be permanently injured by hot

suitable for potable (drinkable) water such as copper,

water than others. These include the elderly, children,

www.americanwaterheater.com

11

Page 11
Image 11
American Water Heater 1010 319869-000 Water Piping Mixing Valve Usage, Suggested Piping Arrangement For TOP Connections