Symptom-to-FRU Index
The
Note: Perform the FRU replacement or actions in the sequence shown in the “FRU/Action” columns. If a FRU replacement did not solve the problem, put the original part back in the WorkPad z50. Do not replace a nondefective FRU.
This index can also help you determine the next possible FRUs to be replaced when servicing the WorkPad z50.
Numeric error codes show the errors detected in system operation. In the following error codes, X can be any number. If no codes are available, use narrative symptoms. If the symptom is not listed, go to “Undetermined Problems” on page 26.
Note: For IBM devices not supported by diagnostic codes in WorkPad computers, see the manual for that device.
Numeric Error Codes
Symptom / Error
1XX
101 IR error
101 IR error
2XX
201 checksum error
202 DRAM test error (on board)
203 DRAM test error (DRAM module)
204 VRAM test error
201 ROM checksum error
202 DRAM test error (on board DRAM)
203 DRAM test error (DRAM module)
204 VRAM test error
3XX
301 Keyboard error
301 Keyboard error
4XX
FRU / Action in Sequence
Mainboard
1.Reinstall ROM card
2.ROM card
3.Mainboard
Mainboard
1.Reinstall DRAM module
2.DRAM module
3.Mainboard
Mainboard
1.Reinstall keyboard
2.Keyboard
3.Mainboard
WorkPad z50 Mobile Companion | 21 |