IBM Z50 manual Check for worn, frayed, or pinched cables

Models: Z50

1 77
Download 77 pages 38 Kb
Page 14
Image 14

The guide consists of a series of steps presented in a checklist. Begin the checks with the power off, and the power cord disconnected.

Checklist:

1.Check exterior covers for damage (loose, broken, or sharp edges).

2.Power-off the computer. Disconnect the power cord.

3.Check the power cord for:

a.A third-wire ground connector in good condition. Use a meter to measure third-wire ground continuity for 0.1 ohm or less between the external ground pin and frame ground.

b.The power cord should be the appropriate type as specified in the parts listings.

c.Insulation must not be frayed or worn.

4.Remove the cover.

5.Check for any obvious non-IBM alterations. Use good judgment as to the safety of any non-IBM alterations.

6.Check inside the unit for any obvious unsafe conditions, such as metal filings, contamination, water or other liquids, or signs of fire or smoke damage.

7.Check for worn, frayed, or pinched cables.

8.Check that the power-supply cover fasteners (screws or rivets) have not been removed or tampered with.

© Copyright IBM Corp. 1998

xv

Page 14
Image 14
IBM Z50 manual Check for worn, frayed, or pinched cables