IBM Z50 manual Intermittent Problems, Undetermined Problems

Models: Z50

1 77
Download 77 pages 38 Kb
Page 41
Image 41

Intermittent Problems

Intermittent system hang problems can be caused by a variety of reasons that have nothing to do with a hardware defect, such as: cosmic radiation, electrostatic discharge, or software errors. FRU replacement should be considered only when a recurring problem exists.

When analyzing the intermittent problem, do the following:

1.Run the diagnostic test for the mainboard in loop mode.

2.If no error is detected, do not replace any FRUs.

3.If any error is detected, replace the FRU shown by the FRU code. Rerun the test to verify that no more errors exist.

Undetermined Problems

You are here because the diagnostic tests did not identify which adapter or device failed, installed devices are incorrect, a short circuit is suspected, or the system is inoperative. Follow these procedures to isolate the failing FRU (do not isolate nondefective FRUs).

Verify that all attached devices are supported by the WorkPad z50.

Verify that the power supply being used at the time of the failure is operating correctly. (See “Power Systems Checkout” on page 9.)

1.Enter suspend mode.

2.Visually check them for damage. If any problems are found, replace the FRU.

3.Remove or disconnect all of the following devices:

a.Non-IBM devices

b.Devices attached to the cradle

c.External devices

d.Battery pack

e.DRAM

f.PC Cards

g.Compact Flash Cards

4.Turn on the WorkPad z50.

5.Determine if the problem has changed.

6.If the problem does not reoccur, reconnect the removed devices one at a time until you find the failing FRU.

7.If the problem remains, replace the following FRUs one at a time. Do not replace a nondefective FRU.

a.Mainboard

b.LCD assembly

26 IBM WorkPad z50, Mobile Companion 26