Operational Conditions
Condensation
Moisture from the products of combustion condenses on the tank surface and the outside jacket of the water heater and forms drops of water which may fall onto the burner or other hot surfaces. This will produce a “sizzling” or “frying” noise. This condensation is
normal and should not be confused with a leaking
tank. Condensation may increase or decrease at different times of the year.
High efficient energy saver water heaters will produce larger amounts of condensation on initial
Important: It is always recommended that a suitable drain pan be installed under the water heater to protect the area from water damage resulting from normal condensation production, a leaking tank or piping connections. Refer to “Location Requirements” on page
4.Under no circumstances is the manufacturer to be held responsible for any water damage in connection with this water heater.
Water Heater Sounds
During the normal operation of the water heater, sounds or noises may be heard. These noises are common and may result from the following:
1.Normal expansion and contraction of metal parts during periods of
2.Condensation causes sizzling and popping within the burner area and should be considered normal.
3.Sediment buildup in the tank bottom will create varying amounts of noise and may cause premature tank failure. Drain and flush the tank as directed under “Draining and Flushing”.
Smoke/Odor
The water heater may give off a small amount of smoke and odor during the initial
Safety Shut-off
This water heater is designed to automatically
1.The pilot flame is extinguished for any reason.
2.The water temperature exceeds 180°F (83°C).
3.Excessive combustion chamber temperatures.
4.The ignition of flammable vapors.
A thermocouple is used to determine if a pilot flame is present and will shut off the gas supply to the main burner and the pilot burner if the flame is absent. In addition, as part of the Flame Guard® Safety System, this thermocouple is equipped with a thermal fuse
designed to shut off the gas supply to the main burner and pilot light in the event a flammable vapor incident occurs or due to poor combustion caused by a blocked vent or insufficient combustion air. If the fuse opens, the water heater cannot be used unless the thermocouple is replaced by a qualified service technician. Contact the Product Service and Support Department for service information at
A high temperature limit switch or ECO (Energy Cut Off) in the tank is used to shut off the unit if the water temperature exceeds 180°F (83°C). The ECO is a single use switch and requires complete replacement of the entire thermostat. If the ECO should function, the water heater cannot be used until the thermostat is replaced by a qualified service technician. Contact your local dealer for service information.
Anode Rod/Water Odor
Each water heater contains at least one anode rod, which will slowly deplete while protecting the
permanently as it will void any warranties, stated or
implied. The parts list includes a special anode that can be ordered if water odor or discoloration occurs. This rod may reduce but not eliminate water odor problems. The water supply system may require special filtration equipment from a water conditioning company to successfully eliminate all water odor problems.
Artificially softened water is exceedingly corrosive because the process substitutes sodium ions for magnesium and calcium ions. The use of a water softener may decrease the life of the water heater tank.
The anode rod should be removed from the water heater tank every 3 years for inspection. If the rod is more than 50% depleted, the anode rod should be replaced.
In replacing the anode:
1.Turn off gas supply to the water heater.
2.Shut off the water supply and open a nearby hot water faucet to depressurize the water tank.
3.Drain approximately 5 gallons of water from tank (Refer to “Draining and Flushing” for proper procedures). Close drain valve.
4.Remove old anode rod.
5.Use Teflon® tape or approved pipe sealant on threads and install new anode rod.
6.Turn on water supply and open nearby hot water faucet to purge air from water system.
7.Restart the water heater as directed under “Operating Your Water Heater.” See the "Repair Parts Illustration" for anode rod location on page 28.