American Water Heater ABCG3 instruction manual Technical Data Venting

Models: BCG3 ABCG3

1 52
Download 52 pages 59.75 Kb
Page 19
Image 19

TABLE 8. TECHNICAL DATA VENTING (Continued)

MODEL (A)BCG3100T2506NOX

Input: 250,000 Btu/hr

 

 

 

 

 

 

total Vent Height (Feet)

 

 

 

 

Vent Connector Size: 6 inches

 

 

 

6

8

10

15

 

20

 

30

50

100

 

 

 

input Btuh/hrRise

 

 

Vent Connector Diameter (Inches)

 

 

 

 

 

 

 

 

250,000

 

1 Ft

 

8

8

7

7

 

7

 

6

6

6

 

 

 

250,000

 

2 Ft

 

7

7

7

7

 

6

 

6

6

6

 

 

 

250,000

 

3 Ft

 

7

7

7

7

 

6

 

6

6

6

 

Number

Combined Input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

250 of Heaters

in Thousands of Btu/hr

 

 

 

 

manifold and Common Vent Diameter (Inches)

 

 

2

 

500,000

 

 

 

9

9

9

8

 

8

 

7

7

7

 

3

 

750,000

 

 

 

12

12

10

10

 

10

 

9

8

8

 

4

 

1,000,000

 

 

 

14

14

12

12

 

10

 

10

9

9

 

MODEL (A)BCG3100T2756NOX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input: 275,000 Btu/hr

 

 

 

 

 

 

total Vent Height (Feet)

 

 

 

 

Vent Connector Size: 6 inches

 

 

 

6

8

10

15

 

20

 

30

50

100

 

 

 

input Btu/hr

 

rise

 

 

Vent Connector Diameter (Inches)

 

 

 

 

 

 

275,000

 

1 Ft

 

8

8

7

7

 

6

 

6

6

6

 

 

 

275,000

 

2 Ft.

 

8

8

7

7

 

6

 

6

6

6

 

 

 

275,000

 

3 Ft

 

7

7

7

7

 

6

 

6

6

6

 

Number of

Combined Input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

275 Heaters

in Thousands of Btu/hr

 

 

 

 

manifold and Common Vent Diameter (Inches)

 

 

2

 

550,000

 

 

 

10

9

9

8

 

8

 

8

7

7

 

3

 

825,000

 

 

 

12

12

12

10

 

9

 

9

8

8

 

4

 

1,100,000

 

 

 

14

14

14

12

 

12

 

10

9

9

 

MODEL (A)BCG385T3106NOX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input: 310,000 Btu/hr

 

 

 

 

 

 

total Vent Height (Feet)

 

 

 

 

Vent Connector Size: 6 inches

 

 

 

6

8

10

15

 

20

 

30

50

100

 

 

 

input Btu/hr

 

rise

 

 

Vent Connector Diameter (Inches)

 

 

 

 

 

 

310,000

 

1 Ft.

 

9

8

8

8

 

7

 

7

6

6

 

 

 

310,000

 

2 Ft.

 

8

8

8

7

 

7

 

7

6

6

 

 

 

310,000

 

3 Ft.

 

8

8

8

7

 

7

 

7

6

6

 

Number of

Combined Input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

310 Heaters

in Thousands of Btu/hr

 

 

 

 

manifold & Common Vent Diameter

 

 

 

2

 

620,000

 

 

 

10

10

9

9

 

8

 

8

7

7

 

3

 

930,000

 

 

 

14

12

12

12

 

10

 

9

9

8

 

4

 

1,240,000

 

 

 

14

14

14

12

 

12

 

12

10

9

 

MODEL (A)BCG385T3666NOX, (A)BCG385T3906NOX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input: 366,000, 390,000 Btu/hr

 

 

 

 

 

 

total Vent Height (Feet)

 

 

 

 

Vent Connector Size: 6 inches

 

 

 

6

8

10

15

 

20

 

30

50

100

 

 

 

Input Btu/hr

 

rise

 

 

Vent Connector Diameter (Inches)

 

 

 

 

 

 

366,000

 

1 Ft

 

9

9

9

8

 

8

 

8

8

8

 

 

 

390,000

 

1 Ft

 

10

9

9

9

 

8

 

8

8

8

 

 

 

366,000

 

2 Ft

 

9

9

8

8

 

8

 

8

8

8

 

 

 

390,000

 

2 Ft

 

9

9

9

8

 

8

 

8

8

8

 

 

 

366,000

 

3 Ft

 

9

8

8

8

 

8

 

8

8

8

 

 

 

390,000

 

3 Ft

 

9

9

8

8

 

8

 

8

8

8

 

Number of

Combined Input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heaters

in Thousands of Btu/hr

 

 

 

 

Manifold & Common Vent Diameter (Inches)

 

 

2

 

732,000

 

 

 

12

10

10

9

 

9

 

9

8

8

 

 

 

780,000

 

 

 

12

12

10

10

 

9

 

9

8

8

 

3

 

1,098,000

 

 

 

14

14

14

12

 

12

 

10

9

9

 

 

 

1,170,000

 

 

 

14

14

14

12

 

12

 

10

10

9

 

4

 

1,464,000

 

 

 

16

16

14

14

 

14

 

12

12

10

 

 

 

1,560,000

 

 

 

16

16

16

14

 

14

 

12

12

10

 

19

Page 19
Image 19