American Water Heater VG6250T100 installation consideration, Rough In Dimensions, A

Models: VG6250T100

1 60
Download 60 pages 31.81 Kb
Page 9
Image 9
installation consideration

installation consideration

Rough In Dimensions

FIGURE 1A.

Table 1 – Rough-In-Dimensions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Units

 

 

A

 

B

 

C

 

 

D

 

 

E

 

F

 

 

G

 

 

H

I

 

 

 

 

 

 

Inches

 

66.75

 

49.25

 

22.00

 

15.75

 

3.00

 

8.00

 

8.00

 

62.00

 

65.00

 

 

 

 

 

 

cm

 

169.5

 

125.09

 

55.88

 

40.00

 

7.62

 

20.32

 

20.32

 

157.48

 

165.1

 

 

 

 

 

 

Top/Side Inlet and Outlet: 3/4” NPT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas Inlet: 1/2” NPT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 2 – Capacity, Gas and Electrical Characteristics

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Approximate Capacity

 

 

Manifold Pressure

 

Electrical Characteristics

 

 

 

 

 

 

 

 

 

 

U.S. Gals.

 

Liters

 

Gas Type

 

“WC

 

kPA

 

Volts/Hz

 

Amperes

 

 

 

 

 

 

 

 

 

 

50

 

 

 

189

 

 

 

Nat./LP

 

 

0”

 

 

0”

 

120/60

 

 

 

<5

 

 

 

 

 

 

 

 

 

 

All models - Maximum Supply Pressure: 14 inches W.C. (3.48kPa)

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum Supply Pressure for Natural Gas: 3.50” (.87kPa)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum Supply Pressure for Propane Gas: 8.00” (1.99kPa)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum pressure must be maintained under both load and no load (dynamic and static) conditions.

 

 

 

Table 3 – Recovery Capacities - U.S. Gallons/Hr. and Liters/Hr. at Temperature Rise Indicated

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Recovery Capacities

 

 

 

 

 

 

Rating

 

Rating

 

Temp.

F

 

30

 

 

40

 

50

 

60

 

70

 

 

80

 

90

100

110

120

130

140

(Btu/hr)

 

(kW)

 

Rise

 

C

 

17

 

 

22

 

28

 

33

 

 

39

 

 

44

 

50

56

61

67

72

78

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100,000

 

29.3

 

 

 

GPH

 

 

387

 

 

291

 

233

 

194

 

166

 

145

 

129

116

106

97

90

83

 

 

 

 

LPH

 

 

1465

 

1102

 

882

 

734

 

 

628

 

549

 

488

439

401

367

341

314

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Recovery capacity based on 96% thermal efficiency