Fault And Alert Messages (cont)
Call the technical support phone number listed on the back cover for further technical assistance or to locate a qualified service agent in your area.
Possible Causes - Check/Repair | Displayed Fault/Alert Message | |||||
• The control system has detected the Blower Prover Switch |
|
|
|
|
| |
Blower Prover Failure |
| |||||
contacts are closed when they should be open at the beginning of |
| |||||
a heating cycle. |
| Fault occurred 2 mins ago |
|
|
| |
• Pinched/shorted Blower Prover Switch wiring. | The blower prover switch is |
|
| |||
|
| |||||
closed out of sequence. |
|
|
| |||
• Jumper wire connected to the Blower Prover Switch - remove |
|
|
| |||
|
|
|
|
| ||
jumper wire. Jumper wires must never be used, read all Warnings. |
|
|
|
|
| |
• Excessive wind outdoors pressurizing the vent system piping. | Call a service professional: |
|
| |||
• Excessive negative air pressure in the installed space. | Your Company Name Here |
|
| |||
(press [DOWN] for more....) |
|
| ||||
|
|
| ||||
| CHANGE | BACK | ADVANCED |
| ||
|
|
|
|
|
| |
|
|
|
|
|
| |
• The control system has detected the Blower Prover Switch |
|
|
|
|
| |
Blower Prover Open |
| |||||
contacts are remaining open after the control system has |
| |||||
energized the Combustion Blower. |
| Fault occurred 2 mins ago |
|
|
| |
|
|
|
|
| ||
• Loose or open wiring to the Blower Prover Switch. | The blower prover switch remains |
|
| |||
|
| |||||
open after the blower has been |
|
| ||||
• Blower Prover Switch air sensing tube disconnected, kinked, filed |
|
| ||||
energized. |
|
|
| |||
with condensate, damaged or leaking - repair or replace tube. |
|
|
|
|
| |
• Combustion Blower is not running when energized. | Call a service professional: |
|
| |||
• Loose or open wiring to Combustion Blower. | Your Company Name Here |
|
| |||
(press [DOWN] for more....) |
|
| ||||
|
|
| ||||
| CHANGE | BACK | ADVANCED |
| ||
|
|
|
|
|
| |
|
|
|
|
|
| |
• The control system has detected the Blocked Intake Air Switch |
|
|
|
|
| |
Blocked Air Intake |
| |||||
contacts are open. |
| |||||
• Loose or open wiring to the Blocked Intake Air Switch. |
| Fault occurred 2 mins ago |
|
|
| |
The combustion air intake is |
|
| ||||
• Excessive equivalent pipe length, exceeded the maximum number |
|
| ||||
restricted. |
|
|
| |||
|
|
| ||||
of 90° elbows or wrong pipe size used in the intake air piping |
|
|
| |||
|
|
|
|
| ||
system. |
|
|
|
|
| |
• Excessive negative air pressure in the installed space. | Call a service professional: |
|
| |||
| Your Company Name Here |
|
| |||
| (press [DOWN] for more....) |
|
| |||
|
|
| ||||
| CHANGE | BACK | ADVANCED |
| ||
|
|
|
|
|
| |
|
|
|
|
|
| |
• The control system has detected the ECO (energy cut out) Switch |
|
|
|
|
| |
Energy Cut Out (ECO) | ||||||
contacts are open. | ||||||
• The ECO switch is a normally closed switch that opens on a |
| Fault occurred 2 mins ago |
|
|
| |
Tank temperature is excessive. |
|
| ||||
temperature rise to prevent excessive water temperature in the |
|
| ||||
The water heater has been |
|
| ||||
storage tank. The ECO switch is inside the Temperature Probe |
|
| ||||
disabled. |
|
|
| |||
(two red wires). |
|
|
| |||
|
|
|
|
| ||
• Loose or open wiring to the ECO switch in the Temperature Probe | Call a service professional: |
|
| |||
- two red wires. | Your Company Name Here |
|
| |||
| (press [DOWN] for more....) |
|
| |||
|
|
|
CHANGE BACK ADVANCED