American Water Heater VG6250T100 Blower Prover Failure, Blower Prover Open, Blocked Air Intake

Models: VG6250T100

1 60
Download 60 pages 31.81 Kb
Page 55
Image 55
Fault And Alert Messages (cont)

Fault And Alert Messages (cont)

Call the technical support phone number listed on the back cover for further technical assistance or to locate a qualified service agent in your area.

Possible Causes - Check/Repair

Displayed Fault/Alert Message

• The control system has detected the Blower Prover Switch

 

 

 

 

 

Blower Prover Failure

 

contacts are closed when they should be open at the beginning of

 

a heating cycle.

 

Fault occurred 2 mins ago

 

 

 

• Pinched/shorted Blower Prover Switch wiring.

The blower prover switch is

 

 

 

 

closed out of sequence.

 

 

 

• Jumper wire connected to the Blower Prover Switch - remove

 

 

 

 

 

 

 

 

jumper wire. Jumper wires must never be used, read all Warnings.

 

 

 

 

 

• Excessive wind outdoors pressurizing the vent system piping.

Call a service professional:

 

 

• Excessive negative air pressure in the installed space.

Your Company Name Here

 

 

(press [DOWN] for more....)

 

 

 

 

 

 

CHANGE

BACK

ADVANCED

 

 

 

 

 

 

 

 

 

 

 

 

 

• The control system has detected the Blower Prover Switch

 

 

 

 

 

Blower Prover Open

 

contacts are remaining open after the control system has

 

energized the Combustion Blower.

 

Fault occurred 2 mins ago

 

 

 

 

 

 

 

 

• Loose or open wiring to the Blower Prover Switch.

The blower prover switch remains

 

 

 

 

open after the blower has been

 

 

• Blower Prover Switch air sensing tube disconnected, kinked, filed

 

 

energized.

 

 

 

with condensate, damaged or leaking - repair or replace tube.

 

 

 

 

 

• Combustion Blower is not running when energized.

Call a service professional:

 

 

• Loose or open wiring to Combustion Blower.

Your Company Name Here

 

 

(press [DOWN] for more....)

 

 

 

 

 

 

CHANGE

BACK

ADVANCED

 

 

 

 

 

 

 

 

 

 

 

 

 

• The control system has detected the Blocked Intake Air Switch

 

 

 

 

 

Blocked Air Intake

 

contacts are open.

 

• Loose or open wiring to the Blocked Intake Air Switch.

 

Fault occurred 2 mins ago

 

 

 

The combustion air intake is

 

 

• Excessive equivalent pipe length, exceeded the maximum number

 

 

restricted.

 

 

 

 

 

 

of 90° elbows or wrong pipe size used in the intake air piping

 

 

 

 

 

 

 

 

system.

 

 

 

 

 

• Excessive negative air pressure in the installed space.

Call a service professional:

 

 

 

Your Company Name Here

 

 

 

(press [DOWN] for more....)

 

 

 

 

 

 

CHANGE

BACK

ADVANCED

 

 

 

 

 

 

 

 

 

 

 

 

 

• The control system has detected the ECO (energy cut out) Switch

 

 

 

 

 

Energy Cut Out (ECO)

contacts are open.

• The ECO switch is a normally closed switch that opens on a

 

Fault occurred 2 mins ago

 

 

 

Tank temperature is excessive.

 

 

temperature rise to prevent excessive water temperature in the

 

 

The water heater has been

 

 

storage tank. The ECO switch is inside the Temperature Probe

 

 

disabled.

 

 

 

(two red wires).

 

 

 

 

 

 

 

 

• Loose or open wiring to the ECO switch in the Temperature Probe

Call a service professional:

 

 

- two red wires.

Your Company Name Here

 

 

 

(press [DOWN] for more....)

 

 

 

 

 

CHANGE BACK ADVANCED

55

Page 55
Image 55
American Water Heater VG6250T100 Blower Prover Failure, Blower Prover Open, Blocked Air Intake, Energy Cut Out ECO, Change