AMX AVS-SL-PR-0401-0601 manual SET Commands, Input Switching, Bytes 3 and, Absolute Volume Level

Models: AVS-SL-PR-0401-0601

1 20
Download 20 pages 63.11 Kb
Page 13
Image 13
SET Commands

SET Commands

SET Commands

Input Switching

The following command switches input sources.

Byte 1 Byte 2 Byte 3

Byte 4

Byte 5(optional)

(Header) (Address) (Video Input) (Audio Input) RGB Delay (see note)

E8

00 to FF 00 to 0A

0 to OA

01 to FF

The Audio Inputs can be switched independently from the Video.

Bytes 3 and 4

01 to 04 correspond to PC inputs 1 to 4

05 to 0A correspond to video inputs 1 to 6 00 for Blank

1F no change

Byte 5

This switches the input sync but holds the RGB in blank for the time period set by the byte. This allows for a clean switch between inputs.

The value is in seconds (e.g. 03 = 3 seconds).

If RGB delay is not required then ignore the 5th byte.

Master Volume (Changes all Input Levels)

The overall Volume level increases 0.5db each time the following command is sent:

Byte 1 Byte 2 Byte 3

(Header) (Address) (Increase)

E8

00 to FF 10

The overall Volume level decreases 0.5db each time the following command is sent:

Byte 1 Byte 2 Byte 3

(Header) (Address) (Decrease)

E8

00 to FF 20

Absolute Volume Level

A Volume value can be set directly using the following command:

Byte 1

Byte 2

Byte 3

Byte 4

(Header)

(Address)

 

(Volume Value)

E8

00 to FF

0F

00 to 5A

with 00 as the loudest (0dB)

AVS-SL-PR-0401-0601

7

 

 

Page 13
Image 13