Programming

System Send_Commands (Cont.)

Command

Description

 

 

'?DE'

Sends the current television power sensor (CC-XPS) delay time string

 

’DE,<Time>’ to the AXC-EM. Set the <Time> value in .10 second

 

increments.

 

Example:

 

SEND_COMMAND AXBTMX,'?DE'

 

The AXB-TM5 sends the current television power sensor delay time to

 

the control system in the ’DE <Time>’ format.

 

 

'DK'

Deletes all direct connections set with the ’DC’ command.

 

Example:

 

SEND_COMMAND AXBTMX,'DK'

 

 

'PIF'

Disables the ’PIN’ command.

 

Example:

 

SEND_COMMAND AXBTMX,'PIF'

 

 

'PIN'

Turns on function that will OR together I/O 1 and frequency sensor to

 

determine actual TV status. I/O 2 will follow ’PON’ and ’POF’

 

commands. The status of this function is stored in permanent memory

 

until changed.

 

Example:

 

SEND_COMMAND AXBTMX,'PIN'

 

 

'POD'

Disables the current ’PON’ (power On) or ’POF’ (power Off) command

 

settings. Channel 255 changes are enabled.

 

Example:

 

SEND_COMMAND AXBTMX,'POD'

 

 

'POF'

Sends IR function 28 (if available) to turn device power off. After three

 

attempts, if the CC-XPS (power sensor) still detects a power-on sta-

 

tus, the television controller starts processing stored buffer com-

 

mands. Then, if another IR function 28 fails to turn the television's

 

power off, the television controller sends a ’PUSH’ and ’RELEASE’ to

 

channel 248 and generates a power failure error. If the device is

 

turned on manually, this command turns television power off unless

 

the television controller receives a ’PON’ (power On) or ’POD’ (disable

 

’POF’) command.

 

Example:

 

SEND_COMMAND AXBTMX,'POF'

 

 

'PON'

Sends IR function 27 (if available) to turn device power on. After three

 

attempts, if the power sensor (CC-XPS) still detects a power-off sta-

 

tus, the television controller starts processing stored buffer com-

 

mands. Then, if another IR function 27 fails to turn the television's

 

power on, the television controller sends a ’PUSH’ and ’RELEASE’ to

 

channel 248 and generates a power failure error. If the device is

 

turned off manually, this command turns television power on unless

 

the television controller receives a 'POF' (power Off) or 'POD' (disable

 

'PON' command) command.

 

Example:

 

SEND_COMMAND AXBTMX,'PON'

 

 

 

12