Programming The MIO R-1 AUDIO

Persistent Serial Commands

There are a select number of persistent commands the MIO R-1 AUDIO recognizes. Establish a HyperTerminal session with your device to use the following commands:

Serial Commands

@BRT

Set Brightness level

 

Syntax:

 

 

"'BRIT-<awake brightness level>,<sleep brightness

 

level>'"

 

 

Variables:

 

 

brightness level # = a value from 0 - 32.

 

"'@BRT-#'"

(Set LED Awake brightness level)

 

"'@BRT-#,#'"

(Set LED Awake brightness level, sleep brightness level)

 

Example:

 

 

(1) "'@BRT-16'"

 

Sets the awake brightness level to 50%.

 

(2) "'@BRT-32,5'"

 

Sets the awake brightness level to 100% and sleep brightness level to

 

approximately 15%

 

 

IRMODE #

Sets the IR transmission frequency to either 455KHz or 38KHz.

 

Syntax:

 

 

"IRMODE #"

 

 

Variables:

 

 

# = 455 or 38

 

 

Example:

 

 

"IRMODE 455"

 

Sets the IR transmission frequency to 455KHz.

 

 

SLEEP-#

Force the device into screen saver mode.

 

Syntax:

 

 

"'SLEEP-#'" (timed sleep; a persistent command)

 

Variables:

 

 

# = 0 - 60 in seconds; time to wait before going to sleep. Default is 30. 0 sets

 

the device to never sleep.

 

Example:

 

 

SEND_COMMAND Panel,"'SLEEP-45'"

 

Forces the device into screen saver mode after 45 seconds.

 

 

 