Firmware Pages and Descriptions
49
TPI-PRO Total Presentation Interface - Pro Edition
Setup Page Elements (Cont.)Connection Status Displays whether the G4 device is communicating externally, the encryption
status of the communicating Master, what connection type is being used
(Ethernet), and of which System the unit is a part.
This visual display of the connection status is also reflected at the upper-right of
each firmware page. This allows the user to have a current visual update of the
panel’s connection status regardless of what page is currently active.
• The message displayed is ’Connected via Ethernet’.
• If no connection can be established by the TPI-PRO, it will continue to try and
establish a connection while displaying: "Attempting via ....".
• The word "Encrypted" appears only when an encrypted connection is
established with a target Master.
• The G4 device must be rebooted before incorporating any panel
communication changes and detecting any active Ethernet connections.
The Ethernet connection is not detected until after a reboot.
Display/Panel Timeout Sets the length of time the TPI-PRO can remain idle before activating the sleep
mode. When the device goes into sleep mode, the LCD is powered-down.
• Press the UP/DN buttons to increase/decrease the time until the TPI-PRO
times out. Range = 0 - 240 minutes.
• Use this button to set the timeout value to zero and disable the sleep mode.
Inactivity Page Flip
Timeout
Sets the number of minutes of inactivity before the G4 device automatically flips
to a pre-selected touch panel page. When the device goes into this inactivity
mode, the LCD does not power-down.
• Press the UP/DN buttons to increase/decrease the time the panel can remain
inactive before it flips to the preset page. Range = 0 - 240 minutes.
• Use this button to set the timeout value to zero and disable the inactivity page
flip mode.
• The touch panel page used for the Inactivity page flip is shown within a small
Inactivity Page field.