Firmware Pages and Descriptions
62 TPI-PRO Total Presentation Interface - Pro Edition
Refer to the Using G4 Web Control® to Interact with a G4 Panel section on page 38 for more detailed instructions on how to use the G4 Web Control page with the new web-based NetLinx Security application.

G4 Web Control Page Elements (Cont.)

G4 Web Control Settings Sets the IP communication values for the TPI-PRO and contains:
Enable/Enabled • The Enable/Enabled button allows you to toggle between the two G4
activation settings:
- Enable - deactivates the G4 Web Control feature on the TPI-PRO.
- Enabled - activates the G4 Web Control feature on the TPI-PRO and allows
an external PC running a VNC client to access the unit, after the remaining
fields are configured.
Network Interface Select A read-only field that displays the method of communication to web.
Wired is selected because it is the only method of communication to the web
(via a direct Ethernet connection). This is a default setting since no wireless
interface is available.
Web Control Name The unique alpha-numeric string that is used as the display name of the
TPI-PRO within the Web Control tab of the new NetLinx Security browser
window. You set the name through the Device Name field on the Protected
Setup Page. This Web Control tab displays a G4 icon alongside the link to the
Web Control Name given to this TPI-PRO.
Web Control Password Allows you to enter the G4 Authentication session password associated for
VNC web access of this TPI-PRO.
Web Control Port Allows you to enter the port value that the VNC Web Server runs on. Default
value is 5900.
Max Number of
Connections
This field displays the maximum number of users that can be simultaneously
connected to the target TPI-PRO via the web. You can set up to 4 connections.
Default value is 1.
Current Connection
Count
This read-only field displays the current number of users connected to the
target TPI-PRO via the web. This value cannot exceed the Maximum number
field.
G4 Web Control Timeout Sets the length of t ime (in minutes) the TPI-PRO can remain idle (no cursor
movements) before the session is closed and the user is disconnected.
• Minimum value = 0 minutes (panel never times-out)
• Maximum value = 240 minutes (panel times-out after 240 minutes/4hours)