FRYER ELECTRICAL SPECIFICATIONS

The ANETS Fryer Model SLG40 requires no external electric power source.

Figure 1 is the wiring diagram of an ANETS SLG40 Fryer.

Figure 1. Fryer Model SLG40 Wiring Diagram

CODE REQUIREMENTS

IMPORTANT: Read the Code Requirements and ALL installation instructions carefully, before starting the installation. Contact the fac- tory (800/ 837-2638) if any problems or ques- tions arise.

The fryer installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1 (latest edition); the Natural Gas Installation Code, CAN/ CGA-B149.1 (latest edition); or the Propane Gas Installation Code, CAN/CGA-B149.2 (latest edition), as applicable, including:

a.Disconnect the fryer and its individual shutoff valve from the gas supply piping system during any pressure testing of the gas supply system at test pressures in excess of ½ psig (3.45 kPa).

b.Isolate the fryer from the gas supply piping system during any pressure testing of the gas

supply system at test pressures equal to or less than ½ psig (3.45 kPa).

c.For fryers utilizing floor casters, the fryer instal- lation shall be made with a connector that complies with the Standard for Connectors for Movable Gas Appliances, ANSI Z21.69 (latest edition) or CAN/CGA 6.16 (latest edition), and a quick-disconnect device that complies with the Standard for Quick-Discon- nect Devices for Use with Gas Fuel, ANSI Z21.41 or CAN/CGA 1-6.9 (latest edition).

d.Restrict the movement of a caster-equipped fryer by using a limiting device (for example, a cable attached both to the fryer and to a fix- ture attached to the site structure) to avoid depending on the connector and the quick- disconnect device or its associated piping to limit fryer movement.

4