FRYER ELECTRICAL SPECIFICATIONS
The ANETS Fryer Model SLG40 requires no external electric power source.
Figure 1 is the wiring diagram of an ANETS SLG40 Fryer.
Figure 1. Fryer Model SLG40 Wiring Diagram
CODE REQUIREMENTS
IMPORTANT: Read the Code Requirements and ALL installation instructions carefully, before starting the installation. Contact the fac- tory (800/
The fryer installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1 (latest edition); the Natural Gas Installation Code, CAN/
a.Disconnect the fryer and its individual shutoff valve from the gas supply piping system during any pressure testing of the gas supply system at test pressures in excess of ½ psig (3.45 kPa).
b.Isolate the fryer from the gas supply piping system during any pressure testing of the gas
supply system at test pressures equal to or less than ½ psig (3.45 kPa).
c.For fryers utilizing floor casters, the fryer instal- lation shall be made with a connector that complies with the Standard for Connectors for Movable Gas Appliances, ANSI Z21.69 (latest edition) or CAN/CGA 6.16 (latest edition), and a
d.Restrict the movement of a
4