INSTALLATION REQUIREMENTS

Install the fryer in accordance with the preceding Code Requirements, as well as the following Installation Requirements.

1.DO NOT install this fryer in a mobile home, trailer, or recreational vehicle.

2.Install this fryer in a location that allows it to be moved away from other adjacent appliances for cleaning and maintenance.

NOTE: If the fryer is installed among a row of appliances (“banked”), with its only convenient movement forward, sufficient room must be available in front of the fryer to permit its separa- tion from adjacent appliances for cleaning and maintenance.

3.Tightly fasten the legs (or casters) to the bot- tom of the fryer using the supplied hardware, to prevent the fryer from tipping, wobbling or rocking when it is in its desired location. Refer to the following Leg Installation Instructions or Caster Installation Instructions for leg or caster attachment and leveling information.

!

CAUTION: Hood make-up air

 

MUST NOT flow in a manner that

 

restricts or impedes the natural flow

 

of combustion or ventilation air.

 

 

4.Confirm that the air from the ventilation hood flowing near the fryer after installation is NOT blowing on the rear of the unit, to prevent affecting the burner flames and possibly causing

control damage.

FRYER RESTRAINING DEVICE INSTALLATION INSTRUCTIONS

!

WARNING

 

Fryers MUST have a movement- limiting (restraining cable) device installed to prevent tipping that causes splashing or spilling its HOT contents.

NOTE: Thismovement-limitingde- vice is to be furnished and in- stalled by the fryer’s installing contractor before the fryer is con- nected to the gas line at its desired location.

1.Install one restraining device connector securely into the structure wall directly behind the fryer’s desired location (Figure 2).

2.Install one restraining device connector on the rear panel of the fryer very close to the quick- disconnect device on the end of the fryer’s gas line.

3.Attach one end of the restraining cable to the wall connector. Attach the other end to the fryer connector.

4.Confirm that the fryer cannot move far enough away from the wall to cause excessive move- ment of the flexible gas line or its associated connectors.

6

Page 6
Image 6
Anetsberger Brothers SLG40 warranty Installation Requirements, Fryer Restraining Device Installation Instructions