Anetsberger Brothers SLG40 warranty Fryer Troubleshooting Guide, Problem, Cause, Remedy

Models: SLG40

1 20
Download 20 pages 62.9 Kb
Page 16
Image 16
FRYER TROUBLESHOOTING GUIDE

FRYER TROUBLESHOOTING GUIDE

All service (repairs or part replacement) must be performed by a qualified Service Agency.

PROBLEM

CAUSE

 

 

REMEDY

 

 

 

 

 

 

Pilot flame does not

1. Dirty/sooty pilot burner.

 

1. Clean the pilot burner. Perform

stay lighted.

 

 

 

 

the Lighting Procedure.

 

2. Low gas supply pressure [less than 6

 

2. Measure the gas supply pres-

 

W.C. for natural gas (11W.C. for pro-

 

 

sure.

 

pane) when all other gas-powered equip-

 

 

Contact your local gas supplier

 

ment is operating.].

 

 

to obtain adequate gas supply

 

 

 

 

 

volume and pressure.

 

3. Pilot flame too small to heat thermo pile.

 

3. Adjust the pilot valve (part of

 

 

 

 

 

the gas safety valve) to in-

 

 

 

 

 

crease the flame size: Un-

 

 

 

 

 

screw and retain the large

 

 

 

 

 

threaded cover; turn the pilot

 

 

 

 

 

valve adjustment screw two

 

 

 

 

 

turns counterclockwise;

 

 

 

 

 

reinstall the threaded cover.

 

4. Pilot flame ‘wavering’ (being blown about

 

4. Block or redirect the draft, to

 

by a draft).

 

 

keep the flame burning steadily.

 

5. Improper thermopile output voltage (must

 

5. Replace the thermopile.

 

be at least 180 millivolts, measured at the

 

 

 

 

 

thermocouple junction block).

 

 

 

 

 

6. High-limit thermostat problem has shut off

 

6. Check for, and repair, any dam-

 

the gas.

 

 

aged high-limit thermostat wir-

 

 

 

 

 

ing. Otherwise, test the high-

 

 

 

 

 

limit thermostat by bypassing

 

 

 

 

 

the high-limit thermostat (black

 

 

 

 

 

and blue wires) at the gas con-

 

 

 

 

 

trol valve with a jumper wire.

 

 

 

 

 

Next, perform the Lighting Pro-

 

 

 

 

 

cedure, to check whether the

 

 

 

 

 

pilot flame lights. If the pilot

 

 

 

 

 

flame lights and stays lit, the

 

 

 

 

 

high-limit thermostat has failed

 

 

 

 

 

and must be replaced.

 

 

 

 

 

 

 

 

 

 

!

CAUTION: DO NOT return

 

 

 

 

 

 

the fryer to normal operation

 

 

 

 

 

 

with its high-limit thermostat

 

 

 

 

 

 

bypassed.

 

 

 

 

 

 

 

 

7. Gas control valve has failed.

 

7. Replace the gas control valve.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

Page 16
Image 16
Anetsberger Brothers SLG40 warranty Fryer Troubleshooting Guide, Problem, Cause, Remedy