UNIT IS CONNECTED TO

6.8.3 Troubleshooting the 24 VAC Circuit in FBRA18 Units

UNIT IS CONNECTED TO

POWER SUPPLY, DRAIN

VALVE IS FULLY CLOSED,

NO WATER IS IN POT,

CONTROLLER IS ON.

Is POWER

No

 

Go to

 

LED lit?

 

 

"A".

 

 

Yes

 

 

Ensure upper water level

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

sensor is not grounded (i.e., 24VAC

Is WATER

No

 

present across sensor and cabinet). If

LED lit?

 

 

sensor is not grounded, most

 

 

 

 

probable cause is failed

 

Yes

 

 

interface board.

 

 

 

 

 

Most probable cause is

 

Is unit filling

No

 

a failed solenoid, but may

 

also be a failed water relay on

with water?

 

 

 

 

interface board or failed

 

 

 

 

 

Yes

 

 

interface board.

 

 

 

 

 

 

Once water

 

 

 

 

reaches upper water

 

No

Is WATER

No

level sensor, does filling stop

and WATER LED

LED lit?

 

go out?

Yes

 

Yes

 

 

Most probable cause is dirty upper

Water leg of 24V

water level sensor, but could also be a

loose connection between sensor and

circuit is OK.

interface board, or a failed interface

 

 

board.

Most probable cause

is failed solenoid, but may also be a failed water relay on interface board.

6-16