4.After the solution simmers for an hour, turn the unit off, allow the solution to cool, then add 2 gallons (7.75 liters) of cold water and stir. Drain the solution and clean the cookpot thoroughly.
5.Rinse the cookpot at least twice by filling with clean water and draining.
6.Reprogram the setpoint to the appropriate temperature.
3.5Shutting Down the Rethermalizer
1.Turn the unit off by pressing the Power switch.
2.If shutting down at the end of the day, turn the gas valve to the OFF position (see illustration below).
Honeywell
ON
OFF
3.Drain and clean the cookpot. NOTE: Do not use deliming solution to clean these units. Use of deliming solution will damage all stainless steel parts.
CAUTION
Do not use deliming solution to clean these units. Use of deliming solution will damage all stainless steel parts.
CAUTION
The electronic circuitry in your controller can be adversely affected by current fluctuations and electrical storms. Should it fail to function or program properly for no apparent reason, unplug the controller and plug it back in to reset it. This could prevent a service call.