Frymaster FBR18 Series manual Operating Instructions, 3.1Introduction, Frymaster

Models: FBR18 Series

1 62
Download 62 pages 63.62 Kb
Page 14
Image 14
CHAPTER 3: OPERATING INSTRUCTIONS

FBR18 & FBRA18 SERIES GAS RETHERMALIZERS

CHAPTER 3: OPERATING INSTRUCTIONS

3.1Introduction

Mechanically, the FBR18 and FBRA18 rethermalizers are virtually identical, the only difference being that the FBRA18 units have an automatic filling (AutoFill) feature. Both units use the same digital temperature controller and mechanical timers.

In operation, a setpoint is programmed into the controller which then regulates burner firing to maintain the water in the cookpot at the desired temperature. Six individual color-coded mechani- cal timers allow different types or quantities of product to be rethermalized simultaneously. The timers are equipped with an alarm to notify the operator that rethermalizing is complete. The prod- uct baskets have color-coded handles that correspond to the timers to eliminate confusion.

3.2FBR18/FBRA18 Digital Controller

 

 

 

 

Celsius or

 

Power

Digital

 

Fahrenheit

 

Switch

Display

 

Display Switch

 

 

9 . 9

9

9

C

 

 

 

 

Frymaster

 

 

 

 

 

Temperature

Setpoint

 

Melt

Heating

or Setpoint

Adjustment

Cycle

Mode

Display Switch

Arrows

 

Switch

Indicator

OPERATING THE FBR18/FBRA18 DIGITAL CONTROLLER

3.1IntroductionWARNING

Ensure the cookpot is filled with water before turning the controller on. “Dry firing” will cause damage to the cookpot!

1.Turn the controller on by pressing the Power 3.2FBR18/FBRA18 Digital Controller switch. The controller software version num- ber will display for 4 seconds in the digital display then change to the last programmed setpoint temperature.

3-1

Page 14
Image 14
Frymaster FBR18 Series manual Operating Instructions, 3.1Introduction, 3.2FBR18/FBRA18 Digital Controller, Frymaster