Frymaster FBR18 Series manual Unit Is Connected To

Models: FBR18 Series

1 62
Download 62 pages 63.62 Kb
Page 41
Image 41
UNIT IS CONNECTED TO

6.8.2 Troubleshooting the 24 VAC Circuit in FBR18 Units

UNIT IS CONNECTED TO

POWER SUPPLY, DRAIN VALVE IS FULLY CLOSED, CONTROLLER IS ON AND IS CALLING FOR HEAT (decimal appears between first

two digits in controller display).

Is 24VAC present on

interface board J3 pin 9 Yes (LED 5 (GV) lit)?

No

NOTE: All voltage measurements must be made within 4 seconds of unit calling for heat. If unit does not fire within 4 seconds, ignition modules will lock out and controller must be turned off then back on to reset.

Is 24VAC

 

 

present across the gas

Yes

24V circuit is

valve main coil (PV

 

OK.

terminal)?

 

 

No

 

 

Probable cause is

 

 

failed wire between

 

 

interface board and gas

 

 

valve.

 

 

Is LED 3 (24V) lit

 

Probable causes are failed

 

No

24V transformer or failed

 

continuously?

 

wiring between transformer

 

 

and interface board.

 

Yes

 

 

 

Is LED 4

Yes

Is LED 2

Yes

(PWR) lit?

 

(PWR) lit?

 

No

 

No

 

Check for 12VDC across interface

 

 

board J2 pins 4 & 5 when controller is calling

 

 

for heat. If 12VDC is not present, probable

Is 24VAC

 

causes are failed controller or failed relay on

present on 25V terminal

Yes

interface board. On later design boards, relay K3

of RIGHT ignition

 

may be replaced. On earlier design boards,

module?

 

the entire interface board must be

 

 

replaced..

No

Probable causes are failed

wiring between blower centrifugal switch and module, failed centrifugal switch, or failed wiring harness.

Is 24VAC

 

 

present on 25V terminal

No

 

of LEFT ignition

 

 

module?

 

 

Yes

 

 

Is 24VAC

 

Probable cause is

present on VALVE

Yes

failed wiring harness.

terminal of ignition

 

 

 

module?

 

 

No

 

 

If fuse is not blown, module has failed.

6-14

Page 41
Image 41
Frymaster FBR18 Series manual Unit Is Connected To