Frymaster FBR18 Series manual Has the correct setpoint, Did burners, Did water reach

Models: FBR18 Series

1 62
Download 62 pages 63.62 Kb
Page 25
Image 25
Has the correct setpoint

WATER NOT HEATING.

AUTOFILL (IF INSTALLED)

WORKED PROPERLY.

Press the Temperature Check button twice to display setpoint.

Has the correct setpoint

No

been programmed?

 

Yes

 

Did burners

No

light?

 

Yes

 

Did water reach

No

setpoint temperature?

 

Yes

 

Problem resolved.

Program setpoint in

accordance with instructions

in Chapter 3.

Refer to troubleshooting guide "BURNERS DO NOT LIGHT".

Insert a good grade thermometer into

cookpot with tip near temperature probe and wait two minutes. Press the Temperature Check button once to display cookpot temperature.

Is temperature

 

There is a problem in

displayed reasonably

No

temperature probe

close to thermometer

 

 

circuit. Call FASC.

reading?

 

 

 

Yes

 

 

Temperature control

 

 

features are working properly.

 

 

If water still fails to reach

 

 

setpoint, call FASC.

 

 

5-4

Page 25
Image 25
Frymaster FBR18 Series manual Has the correct setpoint, Did burners, Did water reach