Problem

NOTE: This guide applies

to FBRA18 units only.

WATER DID NOT SHUT OFF WHEN COOKPOT WAS FULL.

Use bottlebrush to clean

water level sensors.

Problem

Yes

Did water

resolved.

 

stop?

 

 

No

Add 1/8 cup of salt to water in cookpot and stir.

Mineral content of water is

 

 

insufficient for water sensor to

Yes

Did water

detect it. Whenever cookpot is

 

stop?

refilled, add 1/8 cup of salt.

 

 

 

 

No

Remove the cover over the water sensors and thoroughly clean the sensors with a Scotchbrite or similar pad.

If water still does not stop,

probable cause is

failed/loose high water

sensor wiring.

Open control panel by

removing screws in each

upper corner.

Yes

Is WATER

No

LED on interface board

 

 

 

illuminated?

 

Call FASC.

Probable cause is failed

water solenoid.