![3.Place the gas valve in the ON position. Place the controller power switch in the ON position. When the burner lights and continues to burn, compare the indicated pressure to the table below.](/images/new-backgrounds/59911/5991141x1.webp)
3.Place the gas valve in the ON position. Place the controller power switch in the ON position. When the burner lights and continues to burn, compare the indicated pressure to the table below.
Burner Manifold Gas
Pressures
Gas | Pressure | |
Natural | 3.5" W.C. | |
0.8 kPa | ||
| ||
LP | 8.25" W.C. | |
2.5 kPa | ||
|
4.If necessary, adjust the burner gas pressure by removing the cap from the gas valve regulator and turning the regulator screw to obtain the correct pressure. When the correct pressure is obtained, reinstall the cap.
5.Place the controller power switch and the gas valve in the OFF position. Remove the fitting from the pressure tap hole and reinstall the pressure tap plug.