6.8.3 Troubleshooting the 24 VAC Circuit in FBRA18 Units (Continued)

A

Is 24VAC

present on N/O terminal of latch relay?

NOTE: All voltage measurements involving the gas valve leg of the 24V circuit must be made within 4 seconds of unit calling for heat. If unit does not fire within 4 seconds, ignition modules will lock out and controller must be turned off then back on to reset.

Probable causes are failed

No24V transformer or failed wiring between transformer box and

component box.

Yes

Is 24VAC

present on COM No terminal of latch

relay?

Yes

Is 24VAC

present on J1 pin No 3?

If 12VDC is applied across coil, probable cause is failed relay. If not,

Manual background probable cause is failed wiring between controller and latch relay or failed

controller.

Probable causes are failed wiring between terminal block and computer, or failed computer.

Yes

When water level

 

 

is above lower water level

No

Go to

sensor, is CYCLE LED lit?

 

"C".

Yes

 

 

Go to

 

 

"B".

 

 