SECTION 6 GPIB
6-32

6.7.2 Output level subsystem

In the output level subsystem, both :POWer: SOURce and :AMPLitude[:OUT] are valid for the first and second
layers. (When the first layer is PEWer, the SOURce of the second layer cannot be omitted.) The same processing
is performed in either format. :AMPLitude[:OUT] is used in this document.
:AMPLitude[ :OUT]:LEVel <Numeric> <Ampl term> or <Character>
Function Sets the output level.
Parameter <Numeric> = 143 dBm to +23 dBm
<Character> = UP
DOWN
Unit <Ampl term>
(UP,DOWN:<None term>)
Restriction None
:AMPLitude[ :OUT]:LEVel?
Function Reads out the output level.
Response Output level
Restriction None
:AMPLitude[ :OUT]:LEVel:STEP[ :INCRement] <Numeric> <Ampl term>
Function Sets the output level step value.
Parameter <Numeric> = 0.01 dB to 166 dB
Unit <Ampl term>
Restriction Unit is dB, only.
:AMPLitude[ :OUT]:LEVel:STEP[ :INCRement]?
Function Reads out the output level step value.
Response Output level
Restiction None
:AMPLitude[ :OUT]:LEVel:UNIT <Ampl term>
Function Sets the output level unit.
Parameter None
Unit <Ampl term>
Restriction None
:AMPLitude:[ :OUT][ :LEVel]:UNIT?
Function Reads out the output level unit.
Response Output level unit = dB
dBm
dBu
V
mV
uV
Restriction None