Antari Z-1200II, Z-1500II, Z-3000II

on-board DMX settings

Channel A0 - 5 = OFF6 – 249 = Volume Control ( 5% - 95%)250 – 255 = Maximum Volume Output (100%)

The Z-1200 II, Z-1500II & Z-3000II Fog Machines have on-board DMX control. These models use 1 channel to control volume output operation. Each channel has a value range of 0 to 255. Timer functions such as duration and interval can be programmed using the DMX controller or the DMX control software being used by lighting and effects operator.

If Channel A has a value from 0 to 5, the unit is OFF.

Between the values 6 to 249 the volume of fog output is regulated. With 6 being the minimum volume of fog produced and 249 approaching the maximum. The volume output rises as the DMX value is increased.

If Channel A has a value from 250 TO 255, the machine will operate at maximum output.

Note: In the example above, if the machine were assigned the DMX address of 124, Channel A would correspond to DMX address 124.

In general, Antari fog machines with onboard DMX conform to the following performance specifications:

1.Average Operating temperature = 250ºC

2.Fogger can maintain maximum output for 30 seconds or more

3.Fogger can maintain constant output at 25% volume setting (roughly a value of 75).

11