LOW will be displayed until the generator temperature exceeds 250°F (121°C).

 

ERR

 

 

 

 

 

1

2

3

4

UP

DOWN

PROGRAM SINGLE SHOT

 

 

 

ERR (Error) will be displayed if there is a programming parameters error. If this message appears you will have to clear the current parameters.

To clear the unit’s current programming and reset the unit to its factory settings:

1.Turn the unit off.

2.Push the Single Shot and Program buttons simultane- ously and, while turning the unit back on, continue to hold them until you hear the Beep Stop.

3.Check the display:

If the Display shows “ERR” again, repeat steps 1 through 2. If “ERR” still appears on the display, contact your maintenance person or Authorized Service Agency.

If the Display appears normal, try a single shot before attempting to reprogram the unit.

Review the Programming section of this manual and then program the Menu Channel Buttons according to your cook- ing requirements.

 

OPEN

 

 

 

 

 

1

2

3

4

UP

DOWN

PROGRAM SINGLE SHOT

 

 

 

OPEN will be displayed when the thermocouple is “open” or not installed correctly. The unit will not call for heat.

 

PWR

 

 

 

 

 

1

2

3

4

UP

DOWN

PROGRAM SINGLE SHOT

 

 

 

PWR (Power) will be displayed when the supply volt- age is lower than 160 Volts AC or above 265 Volts AC.

 

TEMP

 

 

 

 

 

1

2

3

4

UP

DOWN

PROGRAM SINGLE SHOT

 

 

 

TEMP indicates the control cabinet temperature has exceed- ed 155°F (68°C) causing the unit to shut down.

The TEMP Display indicates that the control cabinet tem- perature has exeeded 155°F (68°C). If this occurs, the unit must be turned off for at least 20 minutes so that it can cool off and reset. If this condition occurs again, contact your maintenance person or Authorized Service Agency.

The Control Board monitors the control cabinet ambient temperature and records the highest temperature. Your ser- vice technician could find such information very useful when troubleshooting the unit.

To determine the control cabinet’s highest temerature since the last reset:

1.Turn the unit OFF.

2.Turn the unit back ON while pressing both the UP and DOWN arrow buttons at the same time.

3.Read the highest control cabinet temperature recorded on the display and release the arrow buttons.

4.Turn the unit OFF again to preserve this record.

To clear/reset this record, press both the UP and DOWN arrow buttons simultaneously (before turning the unit OFF) and the display will show 33°F - indicating that record has been cleared - and then turn the unit OFF.

P/N 1010745 Rev. G 03/06

17