PMF3XS-B, PMP3XS-B, PMJ3XS-B, PMH3XS-B, PML3XS-B, PMG3XS-B operation manual
Models:
PML3XS-B
PMJ3XS-B
PMH3XS-B
PMF3XS-B
PMP3XS-B
PMG3XS-B
1
23
24
24
Download
24 pages
5.78 Kb
17
18
19
20
21
22
23
24
<
>
Troubleshooting
Install
Wiring Diagrams without Integral Switch
SurgeArrest Replacement Modules
Dry Contact Configuration
SPD Wiring
LED Status Indicators
Testing
Precautions
Safety
Page 23
Image 23
Installation and Operation Manual
23
Page 22
Page 24
Page 23
Image 23
Page 22
Page 24
Contents
APC Brick Panel Products
PMF3XS-B PMJ3XS-B PMP3XS-B PMH3XS-B PMG3XS-B PML3XS-B
Installation and Operation Manual
Compliant with UL1449 3rd Edition requirements dated September 29
Table of Contents
DANGER
Precautions
Precautions
LOSS OF BRANCH CIRCUIT POWER/LOSS OF SURGE SUPPRESSION
175 kA 2 seconds
LOSS OF SURGE SUPPRESSION
Precautions
PM3XS-B
Introduction
Testing
Introduction
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
Proper installation is imperative to maximize the modular Surge Protective Device’s SPD’s effectiveness and performance. The installer should follow the steps outlined in this instruction bulletin to ensure proper installation. Read the entire instruction bulletin before beginning the installation. These instructions are not intended to replace national or local electrical codes. Check all applicable electrical codes to verify compliance. Installation of modular surge suppressors should only be performed by qualified electrical personnel
Introduction
DANGER
Inspection
Unpacking and Preliminary Inspection Storage Safety Labels
Identification Nameplate Installation Considerations
Service Clearance Equipment Performance
Voltage Ratings
Electrical
Electrical
Voltage Rating
DANGER
Terminals, Wire Size, and Installation Torque
Branch Circuit Overcurrent Protection and Disconnect Means
Electrical
Location of SPD
Figure 2 SPD Wiring
Location
HAZARDOUS TOUCH VOLTAGE
Grounding
Grounding
the cables are removed, reconnect the cables as marked
Installation
Installation
Conduit Location and Recommendations Special Enclosure Considerations
DANGER
Wiring
Wiring
DANGER
Wiring
Wiring Diagrams without Integral Switch
Figure 3 SIngle-Phase, Three-Wire, Grounded Installation
Figure 4 Three-Phase, Three- or Four-Wire, Grounded Wye Installation
Figure 6 SurgeArrest Module LEDs
LED Status Indicators
Operation
Operation
Operation
Audible Alarm Surge Counter
Table 4 SurgeArrest Replacement Modules
Figure 7 Three-Phase Diagnostic Display Panel with Surge Counter
DANGER
Table 5 Dry Contact Configuration
Dry Contacts
Operation
DANGER
Maintenance
Preventive Maintenance
Maintenance and Troubleshooting
Troubleshooting Flowchart
Troubleshooting
Troubleshooting
Replacement Parts
Installation and Operation Manual
Installation and Operation Manual
Page
APC Worldwide Customer Support