Additional Procedures

 

Battery Verification - 11

 

 

instructions in Bulletins/

 

 

 

Safety.

 

 

1 Set a voltmeter to the 10

 

 

volts DC scale.

 

 

2 Hold the positive probe

 

 

of the voltmeter to the

 

 

positive battery

 

 

terminal and the

 

Positive Probe

negative probe to the

 

negative terminal.

 

 

 

 

3 If the reading is not

 

 

above 5.7 volts,

 

 

recharge (first) or

 

 

replace the battery.