TABLE 3 – Operation Guide
Condition | Solution |
Condensation on windows. | Reduce the setting on the control dial by |
| 1 increment. |
|
|
Lack of humidity. | Increase the setting on the control dial by |
| 1 increment. If the Humidifier Control is |
| already at the maximum setting of “7”, set |
| the Blower Activation Switch to “ON”. The |
| humidifier should be plumbed to hot water |
| when using the Blower Activationfeature. |
|
|
Humidifier does not operate. | Turn dial to “Test/Reset”. Make certain |
(Solenoid does not “click” | HVAC blower is operating. If unit still does |
when control is moved to | not operate, consult a heating contractor. |
“Test/Reset” position.) |
|
|
|
Humidifier won’t shut off. | Turn dial to “Off”. If unit continues to |
| operate, consult a heating contractor. |
|
|
Test mode. | System operation is checked by setting |
| the knob to “Test/Reset”. Make certain |
| HVAC blower is operating. Humidifier will |
| operate for one minute. NOTE: Placing the |
| knob in “Test/Reset” resets the Water |
| Panel change timer. |
|
|
Red “Call Dealer for Service” | Note the error code on the display (E1, E2, |
light flashes (Figure A). | E3 or E4) and call your heating and air |
| conditioning dealer. |
|
|
Yellow “Change Water Panel” | Refer to the Annual Maintenance section |
light flashes (Figure A). | (page 11) for instructions on changing |
| the Water Panel or call your heating and |
| air conditioning dealer for service. After |
| the Water Panel is replaced, turn the |
| Control knob to the “Test/Reset” |
| position until the green “Humidifier On” |
| light flashes, to reset the Water Panel |
| change timer. |
|
|
OPERATING INSTRUCTIONS –
MODELS 350, 360, 400M, 500M, 600M & 700M
FIGURE C – Manual Humidifier Control
Your Aprilaire humidifier is controlled by a Manual Humidifier Control (see Figure C). The Manual Humidifier Control is installed either in the cold air return duct or on an interior wall of the home. With the Manual Humidifier Control, it is important to anticipate a drop in outdoor temperatureand reduce the setting accordingly to avoid excessive condensation, just as with the Digital Humidifier Control installed in Manual Mode (see page 6).
To determine the indoorRH,slowly turn theknobclockwiseandcounterclockwise and listen for 2 clicks. The indoor RH is within the range of the 2 clicks.
CHECK THE HUMIDIFIER OPERATION
DIGITAL HUMIDIFIER CONTROL
Set the knob to “Test/Reset”, make sure that the water saddle valve is open and that there is electricity to the humidifier. The HVAC fan must be running for the humidifier to function. Note: Turning the knob to “Test/Reset” resets the “Change Water Panel” timer. The humidifier will only operate for 1 minute in test mode. (Model 400 and 400M: Floats must be down for the solenoid valve to allow water flow.) Reduce the Humidifier Control setting to the recommended inside RH, depending on the outside temperature. DO
NOT LEAVE IN TEST MODE AS HUMIDIFIER WILL NOT OPERATE.
MANUAL HUMIDIFIER CONTROL
Set the knob to the highest setting, make sure that the water saddle valve is open and that there is electricity to the humidifier. The HVAC system must be operating for the humidifier to function. Confirm that the solenoid valve is energized and water is flowing into the humidifier. Return control knob to desired setting.
- 8 - | - 9 - |