MAINTENANCE & OPERATION (continued)

Heating Tips

Heating in Cooler Weather...

Late night and early morning, generally being the coolest times of the day, are least efficient for heat- ing. For most efficient heating operation, heat pumps should be timed to operate during the warmest, daylight portions of the day. Conversely, if cooling a pool, it is best to run the equipment at night. Please set water pump and heat pump controls accordingly.

Pool/Spa Blankets...

A “solar” blanket will significantly reduce your heating bills. Check with the installing dealer to see if your heat pump was sized to be used in conjunction with a blanket. Blanketed pools will typically lose only 3 - 4° of heat per night versus 8 - 10° overnight with an un-blanketed pool. Reductions of 40-60% on heating bills can be achieved by using blankets. (Idea...Contact AquaCal Customer Support (800-786-7751) to learn about Liquid Blanket innovations.)

Failure to heed the following may result in permanent WARNING ! injury or death.

Improperly used, Pool-Spa blankets can become a drowning risk to people and pets. Blankets are not safety covers. They are not designed to support the weight of a person or pet. Never enter a pool until the blanket is completely removed (under no circumstances should anyone swim under the blanket). Follow all safety recommendations of the blanket manufacturer.

Pool and Spa Combination Heating...

Everything stated for heating a pool applies for heating a spa—only the volume of water being heated is different. Your heat pump comes equipped with two thermostats. One thermostat is for the pool and the other is for the spa. Simply position the pool and spa isolation valves as directed by your installer; select the appropriate thermostat (pool or spa), whichever you are heating, and with electrical power and water flow supplied to the heater, the water will be maintained at set point.

Your system can be automated with the addition of an optional External Flow Switch Kit (P.N. 0040S). Using this option will save you from having to change the thermostat selector switch each time you change from pool-to-spa and back again. Or, add a Universal Heater Controller (P.N. 0097TS) and gain not only automatic thermostat switching, but also automated spa/pool water valve operation. For details, contact the installer, the distributing dealer, or AquaCal Customer Support (800-786-7751).

Spa Heating & Spa Setback Option...

Air blowing into your spa, while it is being brought to temperature, will very often neutralize or partially counteract the heat being put into the spa by the heater; this added heat loss equates to increased time to bring your spa to desired temperature. When heating a spa, be sure to turn off the air blower. Air induced through the spa jets should also be eliminated, during warm-up, whenever possible.

If your heater is being used to only heat a spa, the POOL thermostat can be used as a setback control: simply set the pool control at a point 10-15º F below desired spa heat temperature and select the pool thermostat. This method allows the spa–when not in use–to be held at a heated temperature, but somewhat lower than normal spa-use temperature. One would want to blanket the spa if using this setback method. Using spa setback will result in reduced warm up periods over full, cold starts.

21

Page 21
Image 21
Aquacal 110, 101, 121, 156, 135, 111 owner manual Heating in Cooler Weather, Pool/Spa Blankets, Pool and Spa Combination Heating

121, 111, 101, 135, 110 specifications

Aquacal is a well-known brand in the field of heating and cooling solutions, particularly recognized for its advanced heat pump technology dedicated to pool heating. The Aquacal models 156, 110, 135, and 101,111, offer a range of features and technologies tailored to meet diverse customer needs, ensuring that pools remain at a comfortable temperature regardless of the weather outside.

One of the standout features of Aquacal heat pumps is their energy efficiency. These models are designed to operate using renewable energy, extracting heat from the air, which significantly reduces operational costs compared to traditional gas heaters. The Environmental Protection Agency (EPA) endorses heat pumps, making them an eco-friendly choice for pool heating.

Equipped with advanced digital controls, Aquacal units allow users to easily monitor and adjust settings for optimal performance. The user-friendly interface includes features such as programmable timers, which enable stakeholders to set heating schedules according to their usage patterns, providing both convenience and energy savings. The models are also designed with quiet operation in mind, featuring components that minimize noise, allowing for a peaceful poolside experience.

The Aquacal 156, 110, 135, and 101,111 models are built to withstand various weather conditions, featuring durable casings and components that resist corrosion. This durability is crucial for outdoor installations, ensuring that the units have a long service life with minimal maintenance.

Another key characteristic of these heat pumps is their capacity to function effectively in a wide range of temperatures. This adaptability allows them to provide consistent heating performance even during cooler weather conditions, ensuring that users can enjoy their pools year-round.

Furthermore, Aquacal heat pumps are designed for ease of installation, often fitting into existing plumbing setups without significant modifications. This feature makes them an attractive option for both new pool installations and retrofitting existing systems.

In conclusion, the Aquacal 156, 110, 135, and 101,111 models represent a versatile and energy-efficient choice for pool heating. With their advanced technologies, user-friendly features, and durable construction, they cater to a variety of preferences, making them a popular selection among pool owners looking to maintain comfortable swimming conditions while remaining mindful of energy consumption and costs.