HEATER CONTROLS...continued

Start Up & Setting Operating Controls

Owner-Level Programming Instructions (Complete)

Covered within this section are features and settings typically accessed first by the installer, and then remaining accessible by the end user (the owner). These features reside at the Level-1 access point within the microprocessor. Note: if preferred, all programming may be performed without water flow, waiting to start the water pump as the last step in the set up and run process.

1.Applying Power to The Controller:

A.When power is first applied, the controller performs a lamp test and the display will read [888]. Following [888] the software version will display briefly.

B.The control will then display the actual water temperature, provided the circulating pump is operating, and adequate water is flowing through the heater.

C.If the pool-circulating pump is off, the control will display: [FLO]. This code message indicates no (or insufficient) water is being circulated through the heat pump.

2.MODE Controls Explained, and Starting the Heat Pump:

A.Once electrical power is supplied to the heat pump, sufficient water is circulating, and the heater controller has successfully completed its self-test, the heater is ready to operate.

B.The heat pump is shipped with the controller [MODE] function set to “OFF”. There are two ways to switch the heat pump OFF: First Method- One of the functions of the [MODE] button is “OFF”. Second Method- The thermostat set point can be lowered to a position below the minimum temperature setting (45oF); this action will cause the display to read “OFF”. To switch the unit ON, first use the mode button to select the HEAT mode—for Heat Only models—or, if the heat pump is a Heat and Cool model, use the mode button to select one of the following modes: HEAT, COOL, or ACH (Auto-Changer Over). In the [OFF] mode, the actual water temperature will be displayed as long as the circulating pump is operational and correct water flow is present. In the event water is not circulating through the heat pump (or flow is insufficient), the controller will display the [FLO] (No Water Flow) code message.

C.Using the UP ARROW key, increase the desired temperature until it exceeds the value of the actual temperature displayed. (Note: See # “8,” later in this section, if “000” is displayed upon pressing either the up or down arrow keys.) Once the desired temperature has been entered, the display will read the actual temperature and the heat pump will start to operate. Both the compressor and the fan must be operating before the “Heating” LED will illuminate. (Note: When MODE function is OFF, the current water temperature will be displayed; no functions, values, or programming will be available for adjustment.)

3.Turning The Heat Pump Off:

A.Method 1: using the [MODE] key, press the key until the display reads “OFF” The heater will shut off and remain off until the [MODE] key is used the select an operational mode. This is the preferred method for shutting off the heat pump.

B.Method 2: using the DOWN key, press the key until the desired water temperature reaches 45oF (minimum setting); then, press the DOWN key one more time, causing the display to read “OFF”. This method is typically used in conjunction with 2-wire external controllers; these controllers are equipped with their own thermostats.

(Continued on Next Page)

14

Page 14
Image 14
Aquacal 156, 101, 121, 110, 135, 111 Start Up & Setting Operating Controls, Owner-Level Programming Instructions Complete

121, 111, 101, 135, 110 specifications

Aquacal is a well-known brand in the field of heating and cooling solutions, particularly recognized for its advanced heat pump technology dedicated to pool heating. The Aquacal models 156, 110, 135, and 101,111, offer a range of features and technologies tailored to meet diverse customer needs, ensuring that pools remain at a comfortable temperature regardless of the weather outside.

One of the standout features of Aquacal heat pumps is their energy efficiency. These models are designed to operate using renewable energy, extracting heat from the air, which significantly reduces operational costs compared to traditional gas heaters. The Environmental Protection Agency (EPA) endorses heat pumps, making them an eco-friendly choice for pool heating.

Equipped with advanced digital controls, Aquacal units allow users to easily monitor and adjust settings for optimal performance. The user-friendly interface includes features such as programmable timers, which enable stakeholders to set heating schedules according to their usage patterns, providing both convenience and energy savings. The models are also designed with quiet operation in mind, featuring components that minimize noise, allowing for a peaceful poolside experience.

The Aquacal 156, 110, 135, and 101,111 models are built to withstand various weather conditions, featuring durable casings and components that resist corrosion. This durability is crucial for outdoor installations, ensuring that the units have a long service life with minimal maintenance.

Another key characteristic of these heat pumps is their capacity to function effectively in a wide range of temperatures. This adaptability allows them to provide consistent heating performance even during cooler weather conditions, ensuring that users can enjoy their pools year-round.

Furthermore, Aquacal heat pumps are designed for ease of installation, often fitting into existing plumbing setups without significant modifications. This feature makes them an attractive option for both new pool installations and retrofitting existing systems.

In conclusion, the Aquacal 156, 110, 135, and 101,111 models represent a versatile and energy-efficient choice for pool heating. With their advanced technologies, user-friendly features, and durable construction, they cater to a variety of preferences, making them a popular selection among pool owners looking to maintain comfortable swimming conditions while remaining mindful of energy consumption and costs.