Replacement Parts available from North American
Distributor
CONTROLLED ENERGY CORP.
340 Mad River Park
Waitsfield, Vermont 05673
Phone 800-642-3111
Fax (802) 496-6924
www.controlledenergy.com
techsuppport@controlledenergy.com
VULCANO Termodomésticos S.A.
Estrada de Cacia
3801 - 856 Aveiro - PORTUGAL
GAS LINE SIZE
Natural Gas
Nominal Iron Pipe Size* 1/2" 3/4" 1"
MAXIMUM LENGTH 10' 40' 150'Liquid Propane
Semi-rigid Tubing 1/2" 5/8" 3/4" 7/8"
MAXIMUM LENGTH NOT
RECOMMENDED 20' 60' 150'
* Flex tubing greatly reduces capacity and, therefore, is not recommended.Minimum Vent Size* and Height
Minimum Diameter Minimum Height**5 inches 6 feet*** NOTE: Vent size must not be restricted. Installation must comply with national fuel gas code venting requirements
for a 117,000 Btu Category I appliance and any applicable local codes.
Water Pressure
For installation on well systems, insure that your water pressure is between 30 - 50 psi.
** NOTE: Minimum vent height must be 6 feet, provided there are no elbows. Termination of the vent must be 2
feet above any obstruction within a 10 foot radius of vent pipe. Consult your gas utility or National Fuel Gas Code
if vent will ha v e elbows or sh a r e venting with another appliance. The vent connector should have as much vertical
rise as possible (minimum 12") before any horizontal run.
INSTALLATION CHECKLISTRecycled paper © 2001 Controlled Energy Corporation,
Waitsfield, VT all rights reserved
11&01segapeesELBATECNANETNIAM
RAEYYREVESRAEY2YREVESRAEY5-3YREVEEVLAVRETAWETACIRBUL
†
EVLAVRETAWDLIUBER
†
NEERCSRETLIFRETAWTCEPSNI
†
YLBMESSATOLIPTCEPSNI
†
YLBMESSATNEVTCEPSNI
†
RENRUBNIAMTCEPSNI
†