0 to 100%
0 to 100%
0 to 100%

AV8 Programmer

Future software upgrades can be installed via the RS232 port on the back of the AV8. The following equipment will be required:

!IBM PC compatible computer running Windows 98 or later

!Software – ARCAM AV8 Programmer utility (included on the AV8 CD-ROM)

!Lead – RS232 9-way female D type to 9-way female D type (null modem)

Installation procedure

The AV8 Programmer utility needs to be installed on your PC before you can use it:

!Close down any programs which are running, then insert the CD-ROM into the CD drive

!The setup program normally starts up automatically when the disc is inserted. If this does not happen, you can instruct the PC to install the program as follows:

o Click on ‘Start’ and select ‘Run…’ from the pop-up menu

o In the box, type ‘D:\setup.exe’, where ‘D’ is your CD-ROM drive

o Click ‘OK’

The install process will then begin. You will be prompted for your Name, Organization and Destination Folder for the installation (default is C:\Program Files\Arcam\AV8 Programmer\). Follow the instructions on-screen.

Operation procedure

!Open the AV8 Programmer utility by double clicking the desktop icon, or from the Programs list within the Start menu

!Switch off all the power amps connected to the AV8

!Switch off the AV8

!Connect the RS232 lead from the PC to the RS232 control port on the AV8

!From within the AV8 Programmer software:

o Select the new software file to be uploaded using the ‘Open file’ button

o Select the Com port you are using

!Put the AV8 into program mode:

o Press and hold the program button on the back of the AV8 (located with the video output connections)

o Turn the AV8 on with the program button still pressed

o Wait 5 seconds and then release the program button. The display will remain completely blank and no LEDs will light.

!From within the AV8 Programmer software: o Click ‘Program’

The PC will now upload the software and display the following information:

Connecting:

Programming:

Verifying:

This process will take up to four minutes. When the software has been uploaded the message ‘Status: SUCCESS’ will be displayed.

!Turn the AV8 off and unplug the RS232 lead

!Wait 10 seconds before turning the AV8 back on

If, after programming the AV8 the unit displays “Populating EEPROM” when first turned on, it will be necessary to reset the user configurations within the unit. This is dependent on the degree of the software changes and will not always be necessary.

AV8 Loader (Preset Backup)

The AV8 Loader utility allows the unit settings to be either downloaded from or uploaded to the AV8. The following equipment will be required:

!IBM PC compatible computer running Windows 98 or later

!Software – ARCAM AV8 Loader utility (included on the AV8 CD-ROM)

!Lead – RS232 9-way female D type to 9-way female D type (null modem)

Installation procedure

The AV8 Loader utility can be run directly from the CD- ROM, or you can copy the entire ‘Preset Backup Utility’ folder to your hard drive (e.g. C:\ Program Files \ Arcam \ Preset Backup Utility).

Operation procedure

To run the AV8 Loader program:

!Connect the RS232 lead from the PC to the RS232 control connector on the AV8

!Switch off all the power amps connected to the AV8

!Run the AV8 Loader program:

o Click on ‘Start’ and select ‘Run…’ from the pop-up menu

o In the box, type ‘D:\ Preset Backup Utility \ AV8Loader_GUI.exe’ or the location of the file on the hard drive if not using the CD-ROM

o Click ‘OK’

!Select the Com port you are using: o Select ‘File -> Settings…’

o Select the Com port you are using from the drop down menu

o Close the window

To download the settings from the AV8 to the PC:

!Create a new backup file:

o Select ‘File -> New…’

o Locate a suitable place to save the backup file (e.g. C:\ Program Files \ Arcam \)

o Enter a name for the file in the ‘File name’ box (e.g. AV8.epr). Note the ‘.epr’ name extension

o Click ‘Save’

!Download the AV8 settings:

o Select ‘Transfer -> Download From AV8…’

The AV8 Loader utility will then download the configuration from the AV8 and save it using the filename you gave. Once the setup is read from the AV8 it is automatically stored as a “working file”.

To upload a configuration to the AV8 from the PC:

!Locate the backup file you wish to upload: o Select ‘File -> Open…’

o Locate the folder where the backup file is saved o Select the name of the ‘.epr’ file you wish to

upload

o Click ‘Open’

!Upload the AV8 settings:

o Select ‘Transfer -> Upload To AV8…’

The AV8 automatically resets after the configuration has been uploaded.

Page 10
Image 10
Arcam service manual AV8 Programmer

AV8 specifications

The Arcam AV8 is a high-performance audio-video receiver that has garnered attention for its exceptional sound quality and versatile features, making it a sought-after option for both audiophiles and home theater enthusiasts. Designed to provide an immersive viewing experience, the AV8 is equipped with a range of technologies that enhance its performance.

One of the standout features of the Arcam AV8 is its support for high-definition audio formats. The receiver can decode various lossless audio formats, including Dolby TrueHD and DTS-HD Master Audio, allowing users to experience studio-quality sound. This capability is complemented by its advanced digital signal processing, which ensures that the audio output is clear and dynamic, enhancing the overall entertainment experience.

The AV8 is built with an emphasis on connectivity and flexibility. It boasts multiple HDMI inputs and outputs, facilitating seamless connections to a variety of devices such as Blu-ray players, gaming consoles, and streaming devices. With support for 4K video pass-through, the AV8 is future-proofed for high-definition content, ensuring compatibility with the latest video technologies.

Another notable aspect of the Arcam AV8 is its user-friendly interface. The receiver is equipped with an intuitive on-screen display that simplifies navigation and setup. Additionally, Arcam has incorporated room calibration technology, which analyzes the acoustic properties of the listening environment and adjusts the audio output accordingly. This feature allows for optimal sound reproduction, tailored to the specific characteristics of the room.

The build quality of the AV8 is exceptional; it features a robust chassis designed to minimize vibration and interference, ensuring high-fidelity sound reproduction. The receiver is designed for ease of use, with remote control functionality and smart home integration options, making it convenient to operate alongside other devices.

In summary, the Arcam AV8 is a powerful AV receiver that combines high-definition audio capabilities, extensive connectivity options, and user-friendly features. With its strong emphasis on sound quality and innovative technologies, it stands out in the competitive landscape of home theater equipment, catering to the discerning tastes of audio enthusiasts and casual users alike. Whether for music or movie playback, the AV8 offers a compelling solution for those seeking an elevated audio-visual experience.