Arcam AVR250 Saving Settings and Exit Set-up, ADV 4 - Zone 2 Settings, ADV 5 - Analogue Settings

Models: AVR250

1 44
Download 44 pages 3.26 Kb
Page 17
Image 17
ADV 4 – Zone 2 Settings

ADV 4 – Zone 2 Settings

ZONE2 VOL: Sets the volume for Zone 2.

Max Vol 20–83: Limits the maximum volume setting for Zone 2. This is a useful feature to prevent accidental overdriving of low power-handling speakers, for example.

Fix Vol: This selects between fixed and variable audio output to Zone 2. If NO is selected, the output level can be controlled from Zone 2 or the main system. If you wish to fix the volume level, first set the Zone 2 volume to the desired level, then select YES.

Max On Vol: Limits the maximum volume Zone 2 operates at when it is first switched on. Zone 2 comes on at this volume if the last used volume exceeds this value.

Stand-by: This allows zone 1 (the main zone) to be put into stand-by, either locally only or by Zone 2 as well.

n n

LOCAL ONLY: Only the main zone will be switched into stand-by from the main zone.

ALL OFF: Both the main zone and Zone 2 will be switched into stand-by from the main zone.

Access: This acts as a ‘parental control’ device to disable or enable access to sources for Zone 2.

Press the unwanted source button on the remote control handset or front panel to disable it for Zone 2. Press again to enable the source.

Enabled sources are listed on the ‘Access:’ line of the menu page.

Note: if a source is already in use in Zone 2 when access to it is removed, the source remains active until a different source is selected in that zone. After this time, the original source is unavailable.

ADV 5 – Analogue Settings

Input trims: Allows the adjustment of the input sensitivity of the analogue inputs (in Volts rms) so that each one achieves the optimum dynamic range and sounds similar in loudness to the others.

Available level settings are: LOW 0.5V, MEDIUM 1V, REFERENCE 2V, HIGH 4V. The reference level of 2V should be appropriate for most inputs.

If a source is very quiet compared with the other sources you can increase its loudness by selecting the MEDIUM 1V or LOW 0.5V settings.

Saving Settings and Exit Set-up

You can either save the settings now or exit without saving the changes.

Save Set-up

1.Press MENU to go to the ‘Set-up Menu Index’ at the ‘Save Set-up’ point.

2.Press OK to save.

3.Press OK to select ‘Exit Set-up’ and exit system configuration.

Exit without saving

If you choose to ‘Exit Set-up’ without first saving the changes, then the new settings will be lost.

1.Press MENU to go to the ‘Set-up Menu Index’ at the ‘Save Set-up’ point.

2.Press4to select ‘Exit Set-up’.

3.Press OK when ‘Exit Set-up’ is selected to exit system configuration.

AVR250

E-17

Page 17
Image 17
Arcam AVR250 manual Saving Settings and Exit Set-up, ADV 4 - Zone 2 Settings, ADV 5 - Analogue Settings, Save Set-up