ARTDio IPP 1000 Series
33
5-14.1 Create a Barring Class
1. Select a barring class in the Class Entry in the ‘Class Information’ field and click the “Select”
button.
2. Assign a name for the class: enter the name in the ‘Class Name’ field and click the ‘Add
Name’ button.
3. Add an attribute to the class. You can select either Deny or Accept and click the ‘A dd Attr’
button.
4. At this point, you have successfully selected a barring class and have assigned it an attribute.
You can now assign barring numbers or exception numbers to this attribute using the ‘Add
Barr’ control or ‘Add Excp’ control.
5. After the barring class has been created, you must define which gateways this particular
barring class, applies to.
Examples
Example 1
Assuming the device is located in Shanghai, the setting shown below only allow calls to Beijing and
cell phones. It denies all except 010 and 013 numbers.
Attribute DENY
Barring Table
Exception Table
010
013
Example 2
Assuming the device is located in Shanghai, the setting shown below only allows local calls. Long
distance (0) or international (00) calls would not be allowed.
However, Beijing (10) and Shenzhen (755) are allowed as they are included in the exception table.
Attribute ACCEPT
Barring Table
00
0
Exception Table
010
0755
Example 3
Assuming the device is located in San Jose (USA), the setting shown below only allows local calls.
Long distance (1) or international (001) calls would not be allowed.
However, Beijing (0018610) is allowed as it is included in the exception table.
Attribute ACCEPT
Barring Table
001
1
Exception Table
0018610