Electrical requirements

4-wire connection: Direct wire

3. Make sure that the strain relief screw is

 

tightened.

Important!

Be sure that all terminal block nuts are on

Grounding through

tight and power cord is in the correct position.

 

the neutral

 

conductor is

 

prohibited for (1)

 

new branch-circuit

 

installations, (2)

 

mobile homes, (3) recreational vehicles, and

 

(4)areas where local codes prohibit grounding through the neutral conductor. Prepare minimum 5 ft (1.52 m) of length in order for dryer to be replaced.

First, peel 5” (12.7 cm) of covering material from end. Strip 5 inches of ground wire insulation. After cutting 1 1/2” (3.8 cm) from 3 other wires peel insulation back 1” (2.5 cm). Make ends of 3 wires a hook shape.

Then, put the hooked shape end of the wire under the screw of the terminal block (hooked end facing

rightward) and pinch the hook together and tighten the screw securely.

1.Connect neutral wire (white) of power cord to center terminal block screw.

2.Connect red and black wires to the left and right terminal block screws.

32

Customer Care Center

1-800-898-1879

www.askousa.com

Page 33
Image 33
Asko TL751XXL operating instructions Wire connection Direct wire