Electrical requirements

Option 2: 3-Wire connection with a power supply cord

lf your local codes or ordinances permit the connection of a frame-grounding conductor to the neutral wire, use these instructions.

If your local codes or ordinances do not allow the connection of a frame-grounding conductor to the neutral wire, use the instructions under Section 1: Optional 3- wire connection.

Section 1

Option 3: Optional 3-wire connection

• If your local codes or ordinances do not allow the connection

of a frame-grounding conductor to the

neutral wire, use the instructions under this section.

1.Connect neutral wire (white) of power cord to center terminal block screw.

2.Connect ground wire of appliance and neutral wire of power cord to center terminal block screw.

3.Connect red and black wires to the left and right terminal block screws.

4.Make sure the strain relief screw is tightened. Be sure that all terminal block nuts are on tight and power cord is in the correct position.

5.Connect independent ground wire from external ground connector to proper ground.

35

Customer Care Center

1-800-898-1879

www.askousa.com