LCD
Item |
|
|
| Specification |
|
| ||
|
|
|
|
|
|
|
|
|
Suspend/Standby control | Yes |
| Yes |
| Yes | Yes |
| |
|
|
|
|
|
|
|
|
|
Electrical Specification |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Supply voltage for LCD | 3.3 |
| 3.3 |
| 3.3 | 3.3 |
| |
display (V) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Supply voltage for LCD | 690 |
| 690 |
| 690 | 690 |
| |
backlight (Vrms) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
AC Adapter |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Item |
|
|
| Specification |
|
| ||
|
|
|
|
|
| |||
Vendor & model name |
| Delta |
|
|
| |||
|
| Liteon |
|
|
| |||
|
|
|
|
|
|
|
|
|
Input Requirements |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
Maximum input current (A, |
| 1.5A max@3.5A/100Vac and 240 Vac |
|
| ||||
@100Vac, full load) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Nominal frequency (Hz) |
| 47 - 63 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Frequency variation range |
| 47 - 63 |
|
|
|
|
|
|
(Hz) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Nominal voltages (Vrms) |
| 90 - 264 |
|
|
|
|
|
|
|
|
|
| |||||
Inrush current |
| The maximum inrush current will be less than 50A and 100A when |
| |||||
|
| the adapter is connected to 100Vac(60Hz) and 240Vac(50Hz) |
| |||||
|
| respectively. |
|
|
|
|
|
|
|
|
|
| |||||
Efficiency |
| High efficiency 85% minimum, at 100~240Vac AC input, full load, |
| |||||
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
Output Ratings (CV mode) |
|
|
|
|
|
|
|
|
|
|
|
| |||||
DC output voltage |
| Offers constant voltage 19.0V output source with 65W max output |
| |||||
|
| power capacity. |
|
|
| |||
|
|
|
|
| ||||
Noise + Ripple |
|
|
| |||||
|
|
|
|
|
|
| ||
Output current |
| 0 A (min.) | 3.5A (max.) |
|
|
| ||
|
|
|
|
|
|
|
|
|
Output Ratings (CC mode) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
DC output voltage |
| 18.0 ~ 20.0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Constant output |
| 3.5A |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Dynamic Output Characteristics |
|
|
|
|
|
| ||
|
|
|
|
| ||||
| 3 sec. (@115 Vac and 230Vac full load) |
|
| |||||
|
|
|
|
|
| |||
Hold up time |
| 5ms min. (@115 Vac input, full load) |
|
|
| |||
|
|
|
|
|
|
|
|
|
Over Voltage Protection |
| 25V |
|
|
|
|
|
|
(OVP) |
|
|
|
|
|
|
|
|
|
|
|
| |||||
Short circuit protection |
| Output can be shorted without damage, and auto recovery |
| |||||
|
|
|
|
|
| |||
Electrostatic discharge |
| 15kV (at air discharge) |
|
|
| |||
(ESD) |
| 8kV (at contact discharge) |
|
|
| |||
|
|
|
|
|
|
|
|
|
Dielectric Withstand Voltage |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
Primary to secondary |
| 4242 Vdc for 1 second |
|
|
| |||
|
|
|
|
|
| |||
Leakage current |
| 60uA at 240Vac/60Hz |
|
|
| |||
|
|
|
|
|
| |||
Regulatory Requirements |
| 1. FCC class B requirements (USA) |
|
|
| |||
|
| 2. VDE class B requirements (German) |
|
| ||||
|
| 3. VCCI classII requirements (Japan) |
|
|
| |||
|
|
|
|
|
|
|
|
|
Chapter 1 | 39 |