Terminal Block
Connector
Table 2-1. AT&T PagePal J1 Modular Telephone Jack
Pin
Number Description
1
Not Used.
2C1 control input for Dry Loop (Page Port) activation by
closure (may also be used for Ground Start grounding
point).
3Ring (– polarity is important for Ground Start).
4Tip (+ polarity is important for Ground Start).
5C control input for Dry Loop (Page Port) activation by
contact closure.
6
Not Used.
This is a 20 Pin lug less-type terminal block located at J2 (see
Figure 2-1). See Table 2-2 for a contact descriptions.
Factory Test Connector J3 - No user connections
Wall Plug Transformer -115 VAC, 60 Hz. — U.L. Listed.
Installation 2-7