Table 2-3. AT&T PagePal Troubleshooting Suggestions (continued)
Problem Troubleshooting Steps Solution
Night Bell is not active when it is The input voltage level is too Must be greater than 10 VAC or
intended to be activated with a low or missing. VDC.
low AC or DC voltage. Make sure that the input Verify and correct if needed.
connections are to pins 18 and
19 of J2 (polarity is important).
A higher priority in the PagePal Verify and correct if needed.
is active.
Check the MAIN OUTPUT Correct if needed.
volume control setting.
Night Bell is not active when it is The input voltage level is too Must be greater than 40 VAC
intended to be activated with a low or missing.
Ring voltage.
Make sure that the input Correct if needed.
connections are to pins 19 and
20 of J2.
A higher priority in the PagePal Verify and correct if needed.
is active.
Check the MAIN OUTPUT Correct if needed.
volume control setting.
Alert Tone 2 is not functioning. Check the connection to the Correct if needed.
back panel, pins 1 and 4 of J2.
Check the MAIN OUTPUT Correct if needed.
volume control setting.
Verify using an Ohm meter that Correct if needed.
a contact closure is being pro-
vided from the host equipment.
A higher priority in the PagePal Verify and correct if needed.
is active.